Chapter 4
Diagnostics
39
Code
Description
Problem/Solution
4. If the problem persists, your hard disk drive may
need to be replaced. Contact your service
representative.
053X
Hard Disk drive connection
problem
(This does not apply to
E 800)
(Error code #0530 is the
primary channel cable IDE1
and #0531 is the secondary
channel cable IDE2)
POST has detected a hard disk drive on the second <slave>
position on the IDE cable, but no hard disk has been found
on the first <master> position.
To correct this:
1. If only one hard disk is connected on the cable,
disconnect the hard drive and use the other
connector to re-connect the hard drive into the first
<master> position.
2. If two disks are connected on the cable, verify all
data cables and power cables are firmly connected
for both hard disk drives.
3. If the error message appears just after a hard disk
drive installation, check for master/slave specific
jumper configurations in the hard disk drive
installation manual.
4. If the problem persists, the hard disk drive may need
to be replaced. Contact your service representative.
0540
Hard Disk Controller
resource conflict
POST has detected an address space or IRQ resource
conflict between the integrated hard disk controller and an
accessory board.
To correct this:
1. If the integrated hard disk controller is not needed,
run the Setup Utility to disable it (primary or
secondary).
2. If the integrated hard disk controller is needed, the
accessory board's IRQ and address space must be
reconfigured to use other free resources. Refer to the
accessory board installation manual for information.
0600
Video Memory boot error
(This does not apply to
E 800)
The video memory size detected during POST is smaller than
previously detected.
To correct this:
1. If you have changed your video adapter, press <F4>
to automatically validate the change.
2. If the problem persists, the system board may need
to be replaced. Contact your service representative.
0700
DIMM size boot error
The system memory size detected during the POST is
smaller than previously detected. One or several DIMMs are
Summary of Contents for NetServer e 800
Page 1: ...HP NetServer E 800 Service Manual Online Version 1 0 Last Updated May 2000 ...
Page 27: ...21 3 Parts Information Exploded View Cover and Bezel 1 2 3 4 ...
Page 28: ...Chapter 3 Parts Information 22 Exploded View Drives Shelf Mount 5 6 7 8 9 ...
Page 29: ...Chapter 3 Parts Information 23 Exploded View Power Supply and Drives Cage Mount 10 13 11 12 ...
Page 30: ...Chapter 3 Parts Information 24 Exploded View Exhaust Fan and System Board 14 15 ...
Page 100: ...Chapter 6 Replacing Parts 94 ...