Table 2-28
Jetdirect Menu
(continued)
First level
Second level
Third level
Fourth level
Values
Description
Execution Time [H]
Range: 1 – 24 hours
Default = 1 hour
Specify the length of
time (in hours) that
an embedded test
will be run. If you
select zero (0), the
test runs indefinitely
until an error occurs
or the product is
turned off.
Data gathered from
the HTTP, SNMP,
and Data Path tests is
printed after the tests
have completed.
Execute
No
*
Yes
No
: Do not initiate
the selected tests.
Yes
: Initiate the
selected tests.
Ping Test
Dest Type
IPv4
IPv6
This test is used to
check network
communications. This
test sends link-level
packets to a remote
network host, then
waits for an
appropriate
response. To run a
ping test, set the
following items:
Dest Type
Specify whether the
target product is an
IPv4 or IPv6 node.
Dest IPv4
Range: 0 – 255
Default =
127.0.0.1
Enter the IPv4
address.
Dest IPv6
Select from a
provided list.
Default =
: : 1
Enter the IPv6
address.
Packet Size
Default
=
64
Specify the size of
each packet, in
bytes, to be sent to
the remote host. The
minimum is 64
(default) and the
maximum is 2048.
284
Chapter 2 Solve problems
ENWW
Summary of Contents for LASERJET ENTERPRISE MFP M725dn
Page 1: ...LASERJET ENTERPRISE MFP M725 Troubleshooting Manual M725z M725dn M725f M725z ...
Page 2: ......
Page 3: ...HP LaserJet Enterprise MFP M725 Troubleshooting Manual ...
Page 6: ...iv Conventions used in this guide ENWW ...
Page 32: ...xxx ENWW ...
Page 142: ...110 Chapter 1 Theory of operation ENWW ...
Page 457: ...4 Close the fuser jam access cover 5 Close the fuser door ENWW Clear jams 425 ...
Page 475: ...1 Lift the document feeder latch 2 Open the document feeder cover ENWW Clean the product 443 ...
Page 516: ...484 Appendix A Service and support ENWW ...
Page 545: ......
Page 546: ... 2013 Hewlett Packard Development Company L P www hp com CF066 91023 CF066 91023 CF066 91023 ...