Diagnostic Information
Diagnostic information is gathered by polling a device microcontroller (resulting in a degraded
status if a failure has occurred), or is sent by the device microcontroller, without being polled to
report a failure.
Description
Item
Contains information on model name, part number, serial number, and other information
used to identify the device. This data is also called FRU data. Device identification data
error displays if the data is not present or not readable by the Onboard Administrator.
Device Identification Data
Possible values are OK or Error. View the syslog for errors. Possible reasons for the error
are mismatched firmware or a software or hardware failure.
Device Operational
Indicates if the device has been indicted by the Superdome 2 Analysis Engine.
Device Indictment
Table 7 Subsystems and Devices information
Description
Table
The overall status of all device bays. Possible values are Unknown, OK, Degraded, and
Failed.
Device Bay Overview
All Device Bays
The overall status of the interconnect bays. Possible values are Unknown, OK, Degraded,
and Failed.
Interconnect Bay Overview
All Interconnect Bays
The overall status of the XFM bays. Possible values are Unknown, OK, Degraded, and
Failed.
X–Flex Bay Overview
All XFM Bays
The overall status of the GPSM bays. Possible values are Unknown, OK, Degraded, and
Failed.
GPSM Bay Overview
All GPSM Bays
The overall status of the Power Subsystem of the enclosure. Possible values are Unknown,
OK, Degraded, and Failed.
Power Subsystem
System Status
The overall status of the power supplies. Possible values are Unknown, OK, Degraded,
and Failed.
Power Supply Summary
All Power Supplies
The overall thermal status of the enclosure. Possible values are Unknown, OK, Degraded,
and Failed.
Thermal Subsystem
System Status
The overall status of the fans. Possible values are Unknown, OK, Degraded, and Failed.
Fan Overview
All Fans
72