1.
Use the arrow buttons to navigate to
Fix This
, and press
OK
.
2.
Review and complete the corrective action suggested by the Insight Display. In most cases,
you must either add fans to the enclosure, correct the fan configuration, or remove the indicated
components.
Location errors
Location (installation) errors occur when the component is not installed in the appropriate bay.
Location errors can occur on server blades, storage blades, power supplies, and fans.
To correct a location error:
1.
Use the arrow buttons to navigate to
Fix This
, and press
OK
.
2.
Review and complete the corrective action suggested by the Insight Display. Remove the
indicated component, and install it into the correct bay. The Insight Display will indicate the
correct bay number.
Configuration errors
Configuration errors can occur if the interconnect modules are installed in the wrong bays or if
mezzanine cards are installed in the wrong connectors in the server blade. Configuration errors
can occur on server blades and interconnect modules.
To correct a configuration error:
1.
Use the arrow buttons to navigate to
Fix This
, and press
OK
.
2.
Review and complete the corrective action suggested by the Insight Display. Depending on
the error received, do one of the following:
•
Remove the indicated interconnect module and install it into the correct bay (the Insight
Display indicates the correct bay).
•
Remove the server blade to correct the mezzanine card installation (the Insight Display
will indicate the correct bay). For information on installing the mezzanine card, see the
server-specific user guide on the Documentation CD.
Device failure errors
Device failure errors occur when a component has failed. Device failure errors can occur on all
components, including:
•
Server blades
•
Storage blades
•
Power supplies
•
Interconnect modules
•
Onboard Administrator modules
•
Fans
•
ac power inputs
To correct a device failure error:
1.
Use the arrow buttons to navigate to
Fix This
, and press
OK
.
2.
Review and complete the corrective action suggested by the Insight Display. In most cases,
you must remove the failed component to clear the error.
3.
Replace the failed component with a spare, if applicable.
NOTE:
If the device failure error is an ac power input failure error, you must have the failed
ac input repaired to clear the error.
Insight Display errors
31