Manufacturer : HP
Product Name (prodname) : Integrity BL860c i4
Secondary Product Name : Integrity BL860c i4
Product Number (prodnum) : AM377A
Secondary Product Number : AM377A
Serial number (serial) : SGH2101LRY
Secondary serial number : SGH2101LRY
UUID (uuid) : 59F30FC7-8A4A-11E1-AF3F-DC6163A31240
Secondary UUID : 59F30FC7-8A4A-11E1-AF3F-DC6163A31240
Product ID : 0x711
13.
Remove the Field Upgrade Only sticker from the bezel of the Upgrade Blade Link. This is no longer a
Field Upgrade Blade Link because the Serial Number and UUID have now been programmed on the
Blade Link.
14.
As mentioned earlier, the nPartition configuration of the upgraded server defaults to a single partition.
An example of what might be seen entering the
npar
command from the iLO 3 MP Command Menu
is shown below for an upgrade to a BL890c i4.
[ilo80c16e9877f4] CM:hpiLO-> npar
NPAR
Current nPartition Configuration:
Bay 1 2 3 4
---------------------------------------------------------------------
nPartition : A A A A
Domain MP : yes - - -
Power Off : yes - - -
nPartition Unlocked : - - - -
nPartition Menu:
Current -> AAAA - One 4-Blade System (default)
AACC - Two 2-Blade nPartitions
AACD - One 2-Blade nPartition, and Two 1-Blade nPartitions
ABCC - Two 1-Blade nPartitions, and One 2-Blade nPartition
ABCD - Four 1-Blade nPartitions
Enter new value, or [Q] to Quit:
15.
When a blade is changed from one nPartition to another, the system variable and configuration
information is cleared. This provides a convenient method for ensuring that all Auxiliary blades in the
upgraded server are cleared of stale or inconsistent information. Set the nPartition configuration to
the highest number of partitions possible for the upgraded server. For a BL870c i4 that will be two
(AB) while for a BL890c i4 that will be four (ABCD). The iLO 3 MP will automatically reset for the
change to take effect. An example output is shown below for a BL890c i4. Note that since the
Monarch blade never changes partitions (it always remains in the 'A' partition), that blade will not
have its system environment variables cleared.
[ilo80c16e9877f4] CM:hpiLO-> npar -config abcd -nc
NPAR -config abcd -nc
New nPartition Configuration (* marks modified systems):
Bay 1 2 3 4
---------------------------------------------------------------------
nPartition : * A * B * C * D
-> nPartition Configuration has been updated.
-> iLO will now reset on all modified systems...
Note: System environment variables may be cleared on all modified
72