Installing internal components
Removing the access panel
Procedure
1.
Lift the access panel latch.
2.
Slide the access panel backwards approximately 2 cm (0.75 in).
3.
Remove the access panel by lifting it straight up and off the server blade.
After the access panel is off, you can do the following:
• Add an additional processor (
on page 43).
• Add additional memory DIMMs (
• Add additional mezzanine cards (
on page 54).
Processor and heatsink module
Processor load order
Observe the following guidelines when installing additional processors:
• In a BL860c i4, CPU0 is installed before CPU1.
• In a BL870c i4 or BL890c i4, each blade must have CPU0 installed.
• When adding additional CPUs in a conjoined configuration:
◦ Load both CPU0 and CPU1 in the Monarch blade first.
◦ Load additional CPUs in sequence, from lowest slot-numbered blade to highest.
CAUTION:
The pins on the processor socket are very fragile. Any damage to them might require replacing the
server blade base unit.
CAUTION:
To avoid damage to the processor, verify that the plastic tabs on the processor are pulled fully out
before installation.
Installing internal components
43
Summary of Contents for Integrity BL860c i4
Page 7: ...W 163 Contents 7 ...