5.
Dump the saved PI state to a text file for possible use later. Obtain the dump by executing the
following command:
/opt/network/bin/hpuxpitool –g
This will list out each network instance along with its pre-upgrade MAC address.
6.
Shutdown the OS using a
shutdown
command.
Post-Upgrade Procedure for PI
1.
Dump the new PI state to a file for possible use later. Obtain the dump by executing the following
command:
/opt/network/bin/hpuxpitool –g
This will list out each network instance along with its post-upgrade MAC address.
2.
Disable PI by executing the following command:
/opt/network/bin/hpuxpitool -d
You should see the following:
* Future operations will ask whether to update the backup.
* The requested changes have been applied to the currently
running configuration.
Tunable Value Expression Changes
gio_portable_image (before) 1 1 Immed
(now) 0 0
3.
The networking should be checked to make sure that the original system network instances function
correctly. If the HP-UX boot reports a LAN interface configuration failure, then check the /etc/rc.log file
for the failed instance number which may indicate something like the following example:
ERROR: lan18 interface: ifconfig: no such interface
"/sbin/rc2.d/S340net start" FAILED
Get the MAC address for the failed instance number from the pre-upgrade PI dump and look for that
MAC address in the post-upgrade PI state dump. From that entry, note the new instance number and
edit the HP-UX networking configuration for the failed instance number so that it uses the new
instance number.
Optional components
83
Summary of Contents for Integrity BL860c i4
Page 7: ...W 163 Contents 7 ...