[ilo002264fed1da] CM:hpiLO-> sr
SYSREV
Revisions Active Pending Bay 5 Bay 6 Bay 7 Bay 8
--------------------------------------------------------------------------
--
iLO FW : 01.30.30 01.30.30 01.30.30 01.30.30
01.30.30
System FW : 01.24 01.24 01.24 01.24 01.24
MHW FPGA : 01.14 01.14 01.14 01.14 01.14
Power Mon FW : 03.04 03.04 03.04 03.04 03.04
Front Panel HW : 03.00 03.00 03.00 03.00 03.00
PRS HW : 02.07 02.07 02.07 02.07 02.07
IOH HW : 02.02 02.02 02.02 02.02 02.02
NOTE:
This is just an example so actual version numbers may be different from what is shown.
11.
If the
sr
output indicates that the firmware is not consistent across all of the blades, which should
only be due to a new Upgrade Blade with different firmware version being added, then complete a
second server firmware update. Update the system to the same firmware version used previously for
the existing servers. An example of
sr
output indicating a firmware inconsistency is shown below.
[ilo002264fee2de] CM:hpiLO-> sr
SYSREV
Revisions Active Pending Bay 5 Bay 6 Bay 7 Bay 8
--------------------------------------------------------------------------
--
iLO FW : --.--! 01.30.29 01.30.29 01.01.02
01.01.02
System FW : --.--! 01.24 01.24 01.08 01.08
MHW FPGA : --.--! 01.14 01.14 01.12 01.12
Power Mon FW : 03.04 03.04 03.04 03.04 03.04
Front Panel HW : 03.00 03.00 03.00 03.00 03.00
PRS HW : 02.07 02.07 02.07 02.07 02.07
IOH HW : 02.02 02.02 02.02 02.02 02.02
Note(s):
! = FW mismatch, update needed
NOTE:
This is just an example so actual version numbers may be different from what is shown.
If an update is required, it may need to be completed using the HP SUM Force Install option for both
the iLO 3 and system firmware bundles. HP SUM should detect the mismatch and set the Force
Install option by default. When finished, log back into the iLO 3 MP of the Monarch blade and enter
sr
from the Command Menu to verify that the firmware levels on all conjoined blades are now
consistent and up to date.
12.
Exchange the System Information Parameters by following the steps below. For more information
regarding the information contained in the System Information Parameters, see
a.
Log into the Monarch iLO 3 MP, enter the Command Menu, and execute the command
sysset
.
This will list the system information parameters stored in the Upgrade Blade Link (primary) and
70
Optional components