2–64
HSG80 Array Controller V8.7 Command Line Interface Reference Guide
CLI Command Descriptions
Removes a disk drive from a failedset. The failedset contains disk drives that were:
•
Removed by the controller from RAIDsets and mirrorsets because they failed
•
Manually removed using the SET command (for example, SET mirrorset-name
REMOVE=disk-name)
Enter the DELETE FAILEDSETS command before physically removing failed
members from the storage enclosure for testing, repair, or replacement.
You should consider all disk drives in the failedset as defective. Repair or replace
disks found in the failedset.
Syntax
DELETE FAILEDSETS disk-name
Parameters
disk-name
Identifies the disk you want to delete from the failedset. Only one disk at a time
can be removed from a failedset.
Switches
There are no switches associated with this command.
Example
To delete DISK20200 from the failedset, enter:
DELETE FAILEDSETS DISK20200
See Also
SET FAILEDSETS
SHOW FAILEDSETS
DELETE FAILEDSETS