HSG80 Array Controller V8.7 Command Line Interface Reference Guide
2–95
RUN
•
Automatically test all of the disk units configured
•
Automatically perform thorough tests on all units with write operations
enabled
The standard mode is more flexible and allows you to:
•
Test disks you select
•
Perform tests in read-only mode or write-only mode
•
Provide run time and performance summary option
•
Run in read-only mode
•
DIRECT—A command used to display a list of all executable diagnostic or
utility programs.
•
DSTAT—This is not a user utility. This utility may be used by StorageWorks
authorized service providers only.
•
DWNGRD—This is not a user utility. This utility may be used by
StorageWorks authorized service providers only.
•
FMU—A fault management utility used to control several spontaneous errors.
FMU also displays information regarding the most recent controller and
memory system failure.
•
FRUTIL—A utility used when replacing a failed controller, external cache
battery, or cache module.
•
HSUTIL—A utility used to format a disk device or to download new
firmware to a tape or disk device.
•
VTDPY—A utility used to display the current controller state, performance
data, processor utilization, host post activity and status, device state, logical
unit state, cache performance, and I/O performance.
Refer to the controller troubleshooting reference guide for more information
regarding these utilities.
Switches
There are no switches associated with this command.
Example
To start the DILX diagnostic program, enter:
RUN DILX