HSG80 Array Controller V8.7 Command Line Interface Reference Guide
2–45
CLEAR_ERRORS device-name UNKNOWN
Use this command to force the controller to recognize a failed device, regardless of the
controller’s prior evaluation of the device’s condition.
A device failure may cause the controller to label the device as unknown. When that
happens, the controller does not check the device again to see if it has been repaired or
if the error condition has been corrected. You must enter this command so the
controller can recognize the device after the cause of the error has been corrected.
Syntax
CLEAR_ERRORS device-name UNKNOWN
NOTE: The keyword UNKNOWN cannot be abbreviated.
Parameters
device-name
Identifies the device with the unknown error.
Switches
There are no switches associated with this command.
Example
To force the controller to recognize a previously unknown device named DISK30000,
enter:
CLEAR_ERRORS DISK30000 UNKNOWN
See Also
CLEAR_ERRORS CLI
CLEAR_ERRORS INVALID_CACHE
CLEAR_ERRORS LOST_DATA
CLEAR_ERRORS UNWRITEABLE_DATA
CLEAR_ERRORS
device-name
UNKNOWN