2–88
HSG80 Array Controller V8.7 Command Line Interface Reference Guide
CLI Command Descriptions
Only normal members can be reduced. A normal member is a mirrorset member
whose entire contents are the same as all other normal members within the mirrorset.
NOTE: An error is displayed if you attempt to reduce any mirrorset so that there would not be
any normal member remaining.
Syntax
REDUCE disk-name1 disk-name2 disk-name3...
Parameters
disk-name1 disk-name2 disk-name3...
Specifies the names of the disk or disks to be removed from the mirrorset or
mirrorsets. Multiple members can be removed with the REDUCE command.
Switches
There are no switches associated with this command.
Example
To remove DISK20100, DISK20200, and DISK40200 from their respective
mirrorsets, enter:
SHOW STRIPE1
Name Storageset
Uses
Used
by
---------------------------------------------------------------------------
STRIPE1
stripeset
MIRR1
D104
MIRR2
MIRR3
SHOW MIRRORSETS
Name Storageset
Uses
Used
by
---------------------------------------------------------------------------
MIRR1
mirrorset DISK10100
STRIPE1
DISK20100
MIRR2
mirrorset
DISK10200
STRIPE1
DISK20200
MIRR3
mirrorset
DISK30300
STRIPE1
DISK40200
REDUCE DISK20100 DISK20200 DISK40200
SHOW MIRRORSETS
Name
Storageset
Uses
Used by
---------------------------------------------------------------------------