HSG80 Array Controller V8.7 Command Line Interface Reference Guide
2–127
SET FAILEDSET
2. Make the disk transportable.
SET DISK10000 TRANSPORTABLE.
3. Initialize the disk.
INITIALIZE DISK10000
4. Delete the disk.
DELETE DISK10000
5. Add disk to the Spareset or remove disk from the enclosure.
Example
To enable the automatic spare feature, enter:
SET FAILEDSET AUTOSPARE
To disable the automatic spare feature, enter:
SET FAILEDSET NOAUTOSPARE
See Also
DELETE FAILEDSET
SHOW FAILEDSET