HP PC Blade Switch CLI Reference Guide
www.hp.com
25-1
25
System Management Commands
ping
The
ping
User EXEC mode command sends ICMP echo request packets to another node on the
network.
Syntax
ping
{
ip-address
|
hostname
}[
size
packet_size
] [
count
packet_count
] [
timeout
time_out
]
Parameters
■
ip-address
— IP address to ping.
■
hostname
— Host name to ping. (Range: 1-158 characters)
■
packet_size
— Number of bytes in a packet. The actual packet size is eight bytes larger than
the specified size specified because the device adds header information. (Range: 56-1472
bytes)
■
packet_count
— Number of packets to send. If 0 is entered, it pings until stopped.
(Range: 0-65535 packets)
■
time_out
— Timeout in milliseconds to wait for each reply. (Range: 50 - 65535 milliseconds)
Default Setting
Default buffer size is 56 bytes.
Default number of packets to send is 4.
Default timeout value is 2000 milliseconds.
Command Mode
User EXEC mode
Command Usage
Press
Esc
to stop pinging.
Following are examples of unsuccessful pinging:
■
Destination does not respond
— If the host does not respond, a “no answer from host”
appears in ten seconds.
■
Destination unreachable
— The gateway for this destination indicates that the destination is
unreachable.
■
Network or host unreachable
— The device found no corresponding entry in the route table.
Summary of Contents for Bc1500 - BladeSystem - Blade PC
Page 44: ...2 24 www hp com HP PC Blade Switch CLI Reference Guide 802 1x Commands ...
Page 90: ...5 22 www hp com HP PC Blade Switch CLI Reference Guide Address Table Commands ...
Page 140: ...8 24 www hp com HP PC Blade Switch CLI Reference Guide Ethernet Configuration Commands ...
Page 150: ...9 10 www hp com HP PC Blade Switch CLI Reference Guide GVRP Commands ...
Page 160: ...10 10 www hp com HP PC Blade Switch CLI Reference Guide IGMP Snooping Commands ...
Page 176: ...11 16 www hp com HP PC Blade Switch CLI Reference Guide IP Addressing Commands ...
Page 192: ...13 10 www hp com HP PC Blade Switch CLI Reference Guide Line Commands ...
Page 200: ...14 8 www hp com HP PC Blade Switch CLI Reference Guide Management ACL Commands ...
Page 206: ...15 6 www hp com HP PC Blade Switch CLI Reference Guide PHY Diagnostics Commands ...
Page 214: ...17 4 www hp com HP PC Blade Switch CLI Reference Guide Port Monitor Commands ...
Page 270: ...20 18 www hp com HP PC Blade Switch CLI Reference Guide RMON Commands ...
Page 360: ...24 16 www hp com HP PC Blade Switch CLI Reference Guide Syslog Commands ...