2-8
www.hp.com
HP PC Blade Switch CLI Reference Guide
802.1x Commands
dot1x timeout tx-period
The
dot1x timeout tx-period
Interface Configuration mode command sets the number of
seconds that the device waits for a response to an Extensible Authentication Protocol
(EAP)-request/identity frame from the client before resending the request. To return to the
default configuration, use the
no
form of this command.
Syntax
dot1x timeout tx-period
seconds
no dot1x timeout tx-period
Parameters
■
seconds —
Specifies the time in seconds that the device waits for a response to an
EAP-request/identity frame from the client before resending the request.
(Range: 1-65535 seconds)
Default Configuration
Timeout period is 30 seconds.
Command Mode
Interface Configuration (Ethernet) mode
Command Usage
The default value of this command should be changed only to adjust for unusual circumstances,
such as unreliable links or specific behavioral problems with certain clients and authentication
servers.
Example
The following command sets the number of seconds that the device waits for a response to an
EAP-request/identity frame, to 3600 seconds.
Console(config)#
interface ethernet
1/e16
Console(config-if)#
dot1x timeout tx-period
3600
Summary of Contents for Bc1500 - BladeSystem - Blade PC
Page 44: ...2 24 www hp com HP PC Blade Switch CLI Reference Guide 802 1x Commands ...
Page 90: ...5 22 www hp com HP PC Blade Switch CLI Reference Guide Address Table Commands ...
Page 140: ...8 24 www hp com HP PC Blade Switch CLI Reference Guide Ethernet Configuration Commands ...
Page 150: ...9 10 www hp com HP PC Blade Switch CLI Reference Guide GVRP Commands ...
Page 160: ...10 10 www hp com HP PC Blade Switch CLI Reference Guide IGMP Snooping Commands ...
Page 176: ...11 16 www hp com HP PC Blade Switch CLI Reference Guide IP Addressing Commands ...
Page 192: ...13 10 www hp com HP PC Blade Switch CLI Reference Guide Line Commands ...
Page 200: ...14 8 www hp com HP PC Blade Switch CLI Reference Guide Management ACL Commands ...
Page 206: ...15 6 www hp com HP PC Blade Switch CLI Reference Guide PHY Diagnostics Commands ...
Page 214: ...17 4 www hp com HP PC Blade Switch CLI Reference Guide Port Monitor Commands ...
Page 270: ...20 18 www hp com HP PC Blade Switch CLI Reference Guide RMON Commands ...
Page 360: ...24 16 www hp com HP PC Blade Switch CLI Reference Guide Syslog Commands ...