Functional
Grouping
Denitions
Amplitude
Functions
The
amplitude
softkeys
change
the
input
attenuation
and
scale
of
the
displayed
amplitude
measurement
results
.
Amplitude-Correction
Functions
The
amplitude-correction
functions
enhance
amplitude
measurement
accuracy
.
The
user
can
dene
amplitude
corrections
for
a
specic
frequency-measurement
range
and
enter
the
corrections
through
the
front
panel
keyboard.
The
user-dened
corrections
do
not
aect
the
system
amplitude-correction
factors
.
The
user
calculates
the
amplitude
corrections
for
a
specic
measurement.
The
amplitude
and
related
frequency
values
are
entered
in
a
limit-line
table
,
using
the
limit-line
softkeys
.
The
user
then
converts
the
limit-line
le
into
an
amplitude
correction,
using
the
softkeys
described
in
this
section.
The
operation
of
the
limit-line
softkeys
must
be
understood
before
using
the
softkeys
described
in
this
section.
Bandwidth
Functions
The
bandwidth
softkeys
aect
how
the
resolution
bandwidths
and
video-bandwidths
are
applied
to
an
input
signal.
Calibration
Functions
The
calibration
softkeys
are
used
to
congure
the
system
for
calibration
and
perform
the
calibration
routines
.
The
calibration
routines
can
be
selected
and
run
individually
.
F
or
a
lightwave
signal
analyzer
,
the
lightwave
signal
path
has
been
calibrated
at
the
factory
and
does
not
require
additional
calibration.
However
,
the
RF
or
microwave
signal
path
through
the
HP
70810B
lightwave
section
is
calibrated
using
the
functions
provided
in
this
section.
Display
Functions
The
display
softkeys
control
the
display
of
the
graticule
,
screen
annotation,
display
line
,
and
blanking
of
displayed
trace
information.
Other
display
softkeys
are
used
to
display
text
created
by
the
user
in
the
title
line
at
the
top
of
the
display
.
External-Mixer
Functions
The
external-mixer
softkeys
control
the
measurement
range
when
an
external
mixer
is
used
to
extend
the
spectrum
analyzer
frequency
range
.
The
softkeys
select
the
measurement
range
and
bias
the
external-mixer
gain.
They
also
compensate
for
conversion
loss
at
the
input
port
of
the
external
mixer
interface
module
.
The
external-mixer
softkeys
are
operational
when
the
input
to
an
external
mixer
interface
module
(for
example
,
an
HP
70907A
external
mixer
interface
module)
is
active
.
Press
the
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
select
input
softkey
to
access
the
menu
of
available
input-related
softkeys
.
SoftK
ey
Quick
Reference
3-23