Troubleshooting
Procedures
The
information
in
this
section
covers
the
following
troubleshooting
procedures
for
HP
70000
Series
modular
spectrum
analyzer
systems:
\Troubleshooting
a
Lightwave
Signal
Analyzer"
Categorizing
F
ailures
Troubleshooting
from
the
Front
P
anel
\Troubleshooting
Over
the
HP-IB"
Read
the
preceding
section,
\Troubleshooting
T
ools
,"
before
beginning
the
following
procedures
.
Troubleshooting
a
Lightwave
Signal
Analyzer
The
following
troubleshooting
procedure
can
be
used
to
isolate
a
problem
to
either
the
HP
70810B
lightwave
section
or
the
electrical
spectrum
analyzer
that
is
incorporated
into
the
lightwave
signal
analyzer
.
The
HP
71400C
lightwave
signal
analyzer
combines
an
HP
70810B
lightwave
section
with
an
HP
71210C
microwave
spectrum
analyzer
.
The
HP
71401C
lightwave
signal
analyzer
combines
an
HP
70810B
lightwave
section
with
an
HP
71100C
modular
spectrum
analyzer
.
This
procedure
is
intended
for
use
with
a
lightwave
signal
analyzer
that
has
a
suspected
performance
problem,
yet
has
no
obvious
system
problem.
Troubleshoot
major
lightwave
signal
analyzer
system
failures
just
as
you
would
for
a
spectrum
analyzer
.
Refer
to
the
relevant
section
of
this
chapter
for
system-related
problems
(for
example
,
a
display
,
HP-MSIB
,
or
catastrophic
failure).
Note
The
HP
70810B
lightwave
section
must
be
returned
to
the
factory
for
all
testing,
servicing
and
repair
.
If
a
lightwave
section
is
found
to
be
faulty
,
contact
your
nearest
Hewlett-P
ackard
service
oce
.
The
troubleshooting
procedure
is
divided
into
two
parts
.
Both
portions
of
the
procedure
use
the
same
calibration
routine
to
test
the
performance
of
the
system.
The
rst
part
of
the
procedure
checks
the
performance
of
the
electrical
spectrum
analyzer
while
assuming
good
electrical
switches
in
the
HP
70810B
lightwave
section.
If
no
failure
is
detected,
the
RF
signal
path
through
the
lightwave
signal
analyzer
system
is
functioning
normally
.
If
the
calibration
routine
fails
,
the
second
part
of
the
procedure
is
performed.
The
RF
signal
path
through
the
HP
70810B
lightwave
section
is
bypassed
and
the
calibration
routine
is
repeated.
If
the
calibration
routine
now
passes
,
the
HP
70810B
lightwave
section
is
suspect.
If
the
test
fails
,
the
electrical
spectrum
analyzer
is
suspect.
T
roubleshooting
5-9