Preparing
the
Analyzer
for
Measurements
The
analyzer
requires
proper
connection
of
cables
,
as
shown
in
the
HP
70000
Modular
Spectrum
Analyzer
Installation
and
V
erication
Manual.
Once
the
system
cables
are
connected,
most
analyzer
models
are
ready
for
use
after
they
have
been
calibrated,
continue
at
step
7.
The
following
procedure
provides
some
preliminary
checks
for
nonstandard
analyzers
.
F
ollow
the
procedure
to
activate
the
analyzer
,
and
check
its
hardware
and
error-correction
status
.
1.
Apply
power
to
all
mainframes
and
displays
in
the
system
by
setting
all
LINE
switches
on
(1).
2.
W
ait
about
5
seconds
while
the
analyzer
performs
a
self-check,
then
press
the
instrument-preset
key
,
4
INSTR
PRESET
5
or
4
I-P
5 .
3.
The
analyzer
is
operating
when
a
trace
sweeps
across
the
display
.
The
MEASURE
indicator
LED
illuminates
as
the
sweep
progresses
.
As
an
additional
indicator
,
the
green,
active
(A
CT)
status
indicators
are
lit
on
the
analyzer
modules
,
except
when
the
4
DISPLA
Y
5
key
has
been
pressed.
Also
,
if
your
analyzer
has
more
than
one
signal
path,
for
example
,
more
than
one
RF
input
port
or
more
than
one
IF
module
,
the
green
status
indicator
may
be
o
on
modules
not
passing
or
processing
the
input
signal.
4.
If
your
analyzer
is
sweeping,
skip
to
step
5.
5.
If
the
analyzer
is
not
activated
when
power
is
applied,
press
4
INSTR
5 ,
NNNNNNNNNNNNNNNNNNNNNNNNNNNNN
HP
70900B
.
(If
your
analyzer
does
not
have
an
4
INSTR
5
key
,
press
4
DISPLA
Y
5 ,
then
press
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
NEXT
INSTR
repeatedly
until
the
analyzer
is
activated.)
If
the
analyzer
is
still
not
activated
when
power
is
applied,
inspect
the
rear
panel
HP-MSIB
interconnections
for
tightness
and
then
cycle
power
.
If
you
cannot
activate
the
analyzer
,
press
4
DISPLA
Y
5 ,
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
address
map
to
inspect
the
conguration
of
your
system.
Move
the
highlighted
rectangle
along
the
bottom
row
of
the
address
map
by
turning
the
front
panel
knob
.
The
local
oscillator
module
must
be
in
the
bottom
row
of
the
map
.
If
it
is
not,
change
the
HP-MSIB
row-address
switch
to
row-address
0.
See
the
HP
70000
Modular
Spectrum
Analyzer
Installation
and
V
erication
Manual
for
instructions
.
6.
Inspect
the
status
indicators
on
the
front
panels
of
the
analyzer
modules
.
If
an
error
(ERR)
indicator
is
lit,
press
4
DISPLA
Y
5 ,
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
REPORT
ERRORS
to
learn
what
caused
the
error
and
clear
the
error
indication.
Press
4
MENU
5
or
4
USER
5
to
reactivate
the
analyzer
display
.
If
any
other
error
occurs
,
refer
to
the
HP
70000
Modular
Spectrum
Analyzer
Installation
and
V
erication
Manual
for
installation,
verication,
and
troubleshooting
instructions
.
Refer
to
Chapter
6
for
a
description
of
system
error
messages
.
Note
F
or
an
analyzer
with
an
external
interface
module
for
input,
such
as
an
HP
70907A
external
mixer
interface
module
,
connect
any
signal
within
the
frequency
range
of
your
external
mixer
,
and
tune
to
that
signal.
7.
V
erify
that
the
analyzer
can
display
signals
sent
to
the
RF
INPUT
port.
Connect
the
CALIBRA
TOR
signal
to
the
input
port,
then
press
the
following
keys
.
Press
4
INSTR
PRESET
5
(or
4
I-P
5 )
NNNNNNNNNNNNNN
Freq
NNNNNNNNNNNNNN
SPAN
1
NNNNNNNNNNN
MHz
NNNNNNNNNNNNNNNNNNNN
CENTER
300
NNNNNNNNNNN
MHz
Overview