Introducing
the
HP
4155A/4156A
Overview
of
HP
4155A/4156A
MEASUREMENT
key
group.
Measurement
keys
control
the
measurement,
stress
,
and
integration
time
.
4
Single
5
Executes
the
measurement
once
,
then
returns
to
the
idle
state
(or
standby
state
if
standby
is
enabled
for
the
channel)
after
the
measurement
is
nished.
Measurement
data
is
updated,
so
data
of
previous
measurement
is
lost.
Pressing
the
green
key
,
then
4
Single
5
key
starts
knob
sweep
measurement.
4
Rep eat
5
Starts
and
repeats
the
measurement
continuously
.
Measurement
data
is
updated,
so
data
of
previous
measurement
is
lost.
T
o
stop
the
measurement,
press
4
Stop
5
key
.
4
App end
5
Executes
the
measurement
once
,
then
returns
to
idle
state
(or
standby
state
if
standby
is
enabled
for
the
channel)
after
measurement
is
nished.
Measurement
data
is
appended
to
data
of
previous
measurement.
4
Stop
5
Stops
the
measurement
or
stress
.
Standby
enabled
channels
return
to
standby
state
,
and
other
channels
return
to
idle
state
.
4
Standb
y
5
T
oggles
between
the
standby
enabled
(Standby
indicator
is
lit)
and
disabled
states
.
If
Standby
indicator
is
lit,
then
STBY
ON
channels
change
to
standby
state
(instead
of
idle
state)
when
measurement
or
stress
nishes
.
4
Stop
5
key
has
no
aect
on
standby
state
.
4
Stress
5
F
orces
the
specied
stress
.
The
guide
around
this
key
prevents
you
from
accidently
pressing
the
4
Stress
5
key
.
4
Short
5 ,
4
Medium
5 ,
and
4
Long
5
Sets
the
integration
time
to
SHORT
,
MEDIUM,
or
LONG,
respectively
.
MEASUREMENT
indicator.
This
indicator
lights
when
HP
4155A/4156A
is
in
the
measurement
state
.
HIGH
V
OL
T
A
GE
indicator.
This
indicator
lights
when
a
unit
forces
more
than
40
V
.
Standby
indicator.
This
indicator
lights
when
the
HP
4155A/4156A
is
standby
enabled,
which
means
that
the
channels
that
are
standby
enabled
(STBY
ON )
will
return
to
the
standby
state
after
the
measurement
is
nished.
1-7
Summary of Contents for 4155A
Page 2: ...Semiconductor Parameter Analyzer User s Task Guide ...
Page 6: ......
Page 7: ......
Page 8: ......
Page 9: ......
Page 19: ...Contents ...
Page 20: ...1 Introducing the HP 4155A 4156A ...
Page 47: ...Introducing the HP 4155A 4156A An Overview of Functions ...
Page 48: ...2 Installation ...
Page 84: ...Installation Installing Accessories Attaching HP 16441A R Box to Shielding Box 2 37 ...
Page 94: ...3 Making a Measurement ...
Page 161: ...Making a Measurement Stress Force ...
Page 162: ...4 Analyzing Measurement Results ...
Page 206: ...5 Filer ...
Page 211: ...Filer File Operations Example The following gure shows example that displays le catalog 5 6 ...
Page 233: ...Filer File Operations ...
Page 234: ...6 If Y ou Have A Problem ...
Page 276: ...7 Manual Changes Depending on ROM Version ...
Page 279: ...Manual Changes Depending on ROM Version Change 1 ...