65
2. Highlight the subnet manager that you want to configure from the left-navigation bar.
3. Click into the
Sweep Interval
field.
4. Enter a value that indicates the number of seconds between sweeps of the network.
The default is 10 seconds.
The
Apply
and
Reset
buttons become active if a change is made.
5. Click the
Apply
button to save the changes to the chassis.
Change the Response Timeout of a SM
The response timeout is the maximum time allowed between the port reception of a subnet management
packet and the transmission of the associated response.
The default is 2,000 microseconds.
1. Select
InfiniBand
>
Subnet Management
.
The Subnet Management window appears.
Summary of Contents for 376227-B21 - ProLiant InfiniBand 4x Fabric Copper Switch
Page 10: ...viii ...
Page 20: ...8 ...
Page 44: ...32 ...
Page 50: ...38 ...
Page 56: ...44 ...
Page 72: ...60 ...
Page 92: ...80 ...
Page 104: ...92 ...
Page 116: ...104 ...
Page 122: ...110 ...
Page 130: ...118 ...