148
The Trap Receivers, Insert Trap... window appears.
4. Enter the IP address of the desired Trap Receiver in the
Address
field.
5. Enter the SNMP community string in the
Community
field.
6. Check the
Receive Events
box if you want to enable the Trap Receiver to receive events.
You can also add the Trap Receiver, then enable it later.
7. Click the
Insert
button.
Editing a Current SNMP Trap Receiver
1. Launch Element Manager, if you have not already done so.
2. Select Health --> Trap Receivers.
The Trap Receivers window appears.
Any previously configured Trap Receivers appear in the window.
3. Click in any of the fields to edit them.
•
Click into the
Address
field to change the IP address of a Trap Receiver.
•
Click into the
Version
field to change the SNMP version.
Note
: v2C is the highest supported
version.
•
Click into the
Community
field to change the SNMP community string.
•
Click into the
Receive Events
field to enable or disable the Trap Receiver from receiving
events. The field becomes a drop-down menu when clicked.
Summary of Contents for 376227-B21 - ProLiant InfiniBand 4x Fabric Copper Switch