60043599 • 02 • 03/2021 • en
105
26 Display values
26.1 Special cases
26.1.1 Bar graphs
An explanation on the meaning of the individual bar graphs follows.
The row (section) is fully configured, the section width is set to 0.
The section width can only be set to 0 if the following conditions are met:
• The section is fully configured.
• The section is not grouped with other sections.
Effects:
• The total working width is reduced.
• The section is no longer communicated to the TaskController.
• Actors of this section are no longer selected, sensors of this section are not
longer analysed.
The row (section) is fully configured, the section width is not set to 0.
Effects:
• The section is not subtracted from the working width; the total working width
remains unchanged.
• If a product boom is present, the theoretical placing quantity of these sections is
distributed to all active sections at equal parts.