Filling connection for fresh water tank
1.
Connect the filling hose.
2.
Open the filler valve.
3. Fill the fresh water tank.
¾
Watch the level gauge! No automatic shut-
down when the tank is full!
¾
On machines of the CCS Pro variant the
filling level can be read on the external
control terminal.
4.
Close the filling valve.
5. Uncouple the hose.
6. Close the connection with the cap.
Always have a sufficient amount of fresh water
on board when using the crop protection sprayer.
When filling the spraying mixture container check
and refill also the fresh water tank.
Illuviation of preparations
Illuviation valve
DANGER
Wear appropriate protective clothing for the
illuviation flush in the preparations.
Observe the regulations and notes as well as the
safety data sheet of the crop protection agent
manufacturer!
NOTE
After the preparations have been illuviated,
stirring must be carried out for at least 5 minutes,
or longer depending on the preparations, with
the
Agitator max. stirring
stage in order to achieve
homogeneity in both tanks.
The agitator normally remains switched on from
filling to the end of spraying.
The information provided by the preparation
manufacturer are decisive in this respect.
Crop protection agent and carbonyl diamide are
poured into the illuviation valve, dissolved and
drawn in.
Swing the illuviation valve down by pulling it by
the handle.
106
107
Summary of Contents for LEEB 12 TD
Page 2: ......
Page 5: ......
Page 9: ...5...
Page 27: ...Safety stickers with the addition 2x can be found on either side of the machine 2x 23...
Page 121: ...Diagram a with example 117...
Page 146: ...Suspension cylinder Suspension cylinder 142...
Page 148: ...Parallelogram lock Pendulum lock cylinder Parallelogram Parallelogram 144...
Page 180: ......