Troubleshooting
2
System Errors
PC-P430
17
Error Lamp
Description and Causes
Solutions
3
Deposition of K01 Interlock Relay 1
Turn off the power and check that the contact points on K01 are not damaged.
If the contact points are not damaged, check the wiring/connection between terminals 21 and 22 of K01 and CON3 on the QPW-968 con-
trol board. If these are OK, the board is defective. Replace it.
Function Error of K01 Interlock Relay 1
Check whether the L6 on the QPW-968 control board is lit while the safety cover is closed.
If the LED is lit, go to 1. If not, go to 2.
1. The LED is lit.
The correct signals are input from K01 to the board, but the signals
are not being processed correctly. Replace the board.
2. The LED is not lit.
Check the wiring/connection between terminals 21 and 22 of K01 and
CON3 on the QPW-968 control board. If this is OK, replace K01.
4
Deposition of K02 Interlock Relay 2
Turn off the power and check that the contact points on K02 are not damaged.
If the contact points are not damaged, check the wiring/connection between terminals 21 and 22 of K02 and CON3 on the QPW-968 con-
trol board. If these are OK, the board is defective. Replace it.
Function Error of K02 Interlock Relay 2
Check whether the L7 on the QPW-968 control board is lit while the safety cover is closed.
If the LED is lit, go to 1. If not, go to 2.
1. The LED is lit.
The correct signals are input from K02 to the board, but the signals
are not being processed correctly. Replace the board.
2. The LED is not lit.
Check the wiring/connection between terminals 21 and 22 of K02 and
CON3 on the QPW-968 control board. If this is OK, replace K02.
5
Deposition of S07 Safety Cover Switch (Right)
Error 5 or 6 may occur when the safety
cover is opened slowly.
Check that the contact points of S07 are not damaged.
If the contact points are not damaged, check the wiring/connection between S07 and CON3 on the QPW-968 control board. If this is OK,
the board is defective. Replace it.
6
Deposition of S10 Safety Cover Switch (left)
Error 5 or 6 may occur when the safety
cover is opened slowly.
Check that the contact points of S10 are not damaged.
If the contact points are not damaged, check the wiring/connection between S10 and CON3 on the QPW-968 control board. If this is OK,
the board is defective. Replace it.
7
Failure of Interlock Contactor
Drive Element on the Board
Replace the control board.
8
S03 Cam Switch A Open Failure
S03 Cam Switch A Close Failure
9
S04 Cam Switch B Open Failure
S04 Cam Switch B Close Failure
10
Knife Lock
Summary of Contents for PC-P430
Page 6: ...This page is intentionally left blank ...
Page 7: ...General 1 PC P430 7 1 General PC P430 ...
Page 12: ...1 General PC P430 12 This page is intentionally left blank ...
Page 13: ...General 1 PC P430 13 This page is intentionally left blank ...
Page 14: ...1 General PC P430 14 This page is intentionally left blank ...
Page 15: ...Troubleshooting 2 PC P430 15 2 Troubleshooting PC P430 ...
Page 18: ...2 Troubleshooting PC P430 18 This page is intentionally left blank ...
Page 28: ...2 Troubleshooting PC P430 28 This page is intentionally left blank ...
Page 29: ...Troubleshooting 2 PC P430 29 This page is intentionally left blank ...
Page 30: ...2 Troubleshooting PC P430 30 This page is intentionally left blank ...
Page 31: ...Descriptions of Mechanisms 3 PC P430 31 3 Descriptions of Mechanisms PC P430 ...
Page 47: ...Descriptions of Mechanisms 3 PC P430 47 This page is intentionally left blank ...
Page 48: ...3 Descriptions of Mechanisms PC P430 48 This page is intentionally left blank ...
Page 49: ...Descriptions of Mechanisms 3 PC P430 49 This page is intentionally left blank ...
Page 50: ...3 Descriptions of Mechanisms PC P430 50 This page is intentionally left blank ...
Page 51: ...Electrical Parts Location 4 PC P430 51 4 Electrical Parts Location PC P430 ...
Page 53: ...Electrical Parts Location 4 PC P430 53 This page is intentionally left blank ...
Page 56: ...4 Electrical Parts Location PC P430 56 This page is intentionally left blank ...
Page 57: ...Electrical Parts Location 4 PC P430 57 This page is intentionally left blank ...
Page 58: ...4 Electrical Parts Location PC P430 58 This page is intentionally left blank ...
Page 59: ...Circuit Boards 5 PC P430 59 5 Circuit Boards PC P430 ...
Page 66: ...5 Circuit Boards PC P430 66 This page is intentionally left blank ...
Page 67: ...Circuit Boards 5 PC P430 67 This page is intentionally left blank ...
Page 68: ...5 Circuit Boards PC P430 68 This page is intentionally left blank ...
Page 69: ...Electrical Circuits 6 PC P430 69 6 Electrical Circuits PC P430 ...
Page 72: ...6 Electrical Circuits PC P430 72 This page is intentionally left blank ...
Page 73: ...Electrical Circuits 6 PC P430 73 This page is intentionally left blank ...
Page 74: ...You can download the latest manual http hip horizon co jp Anytime and Anywhere END SHEET ...