E-7
6.1.3. Installing
measuring
unit
①
Install the measuring unit (VP-1U-VP-4U) suitable for the intended flow rate
measurement as follows. Align hook pin on the equipment with the groove on the
measuring unit to insert.
②
Turn the fixing lever to the direction arrow in Fig.3 to complete the installation.
※
when you uninstall the measuring unit, turn the fixing lever to the original position.
Then pull up the measuring unit gently while holding the SF main body.
CAUTION
BE SURE TO FIX MEASURING UNIT.
Make sure that the measuring unit is fixed to the main body by turning the
fixing lever when you install. Carrying or using them without fixing may cause
damage or injury through dropping or turning over
Fig.3 Installing measuring unit
Fig.4 Pouring filming liquid
6.1.4. Pouring
filming
liquid
Put the nozzle of filming liquid bottle, 2 cm to 3 cm, into the measurement gas inlet port on the
left side of the measuring unit. Fill the equipment with filming liquid gradually up to the
liquid level, between 2 blue lines on the liquid level window. Be sure not to create bubbles.
NOTE
Do not put the nozzle more than 4 cm into the measuring unit. It will be
cause of a trouble.
Be sure to use the designated filming liquid Snoop
®
. Use of other soap
water not only causes inadequate filming but contaminates the measuring
unit and deteriorates the packing.
Be sure the liquid level is always between two blue lines when you
measure. The liquid level above or below the upper and lower levels
adversely affect the film creation and measurement accuracy.
①
②
Groove
Hook pin
Filming
liquid
Snoop
®
Connector
Summary of Contents for SF-1U
Page 1: ...FILM FLOW METER SF 1U 2U Instruction Manual CODE I030248700E...
Page 2: ...May 2016 2004 2016 HORIBA STEC Co Ltd...
Page 3: ...J i...
Page 4: ...J ii...
Page 5: ...J iii 1 2 3 4 5 6 7 8 1 40 2 3 4 5 40 6 7 8 9 10 11 12 13...
Page 7: ...J 1 SF 1U SF 2U Snoop Swagelok Company...
Page 8: ...J 2 1 SF VP 1384428 SF 2U 2 0 35 1013 3hPa 1 3 SF 1U SF 2U 1 Snoop 59ml 1 I030248700 1 AC...
Page 10: ...J 4 5 2...
Page 12: ...J 6 6 6 1 6 1 1 6 1 2 AC...
Page 13: ...J 7 6 1 3 VP 1U 4U SF 3 4 6 1 4 2 3cm 4cm Snoop Snoop...
Page 14: ...J 8 6 1 5 VP 1U 3U 6mm 5 6mm VP 4U 10mm 9 10mm 10mm 9 10mm 3L min 2cm VP 1U 2U 1 2mm...
Page 15: ...J 9 6 1 6 25 5 0 35 25 3 6 1 7 3 10 6 2 6 2 1 N2 5 20 1 1...
Page 16: ...J 10 6 2 2 SF 1U 730 1070hPa 1013 3hPa SF 2U 2 730 1070hPa 1013 3hPa 2 6 2 3 2...
Page 19: ...J 13 8 8 1...
Page 20: ...J 14 8 2 A1 A1 A1 120 VP 1U 180 120 180 6 4 120 120 6 4 A1 7 1 3...
Page 21: ...J 15 8 3 A2 A2 A2 120 VP 1U 180 120 180 6 4 7 1 3...
Page 22: ...J 16 8 4 A3 A3 A3 7 1 3 8 5 A4 A4 A4...
Page 23: ...J 17 8 6 8 7 7 1 3...
Page 39: ...E 4 5 Description of each part Fig 2 Description of each part...