3.11
Serial Menu
RS232 / RS485 Serial Port Configuration (Common to all)
RS232 Port
Select the desired functionality. Select either PPP, Serial Gateway or Modbus TCP to
RTU
Data Rate
The serial data rate desired. Serial data rates available range from 110bps to a
maximum of 115,200bps.
Data Format
The data format desired. All the standard data formats are supported.
Flow Control
Selects CTS/RTS or None
RS232 PPP Server (Only RS232)
Username
User name to enter to access RS-232 PPP Server.
Password
Password to access RS-232 PPP Server.
Local IP Address
Select the IP address of the PPP server. The remote device may be made visible on the
Ethernet or Wireless networks by either utilising proxy-arp or routing. The proxy-arp
feature may be enabled by setting the Local IP address the same as the Ethernet IP
Address or the Wireless IP Address. The module will respond on behalf of the remote
device, making it seem like the device is present on the configured network.
Alternatively, if the IP address selected is not the same as the Ethernet or Wireless IP
address, routing is used to pass data to the Ethernet and Wireless ports.
Remote Device IP Address
Select the IP address of the remote device. Ensure this address is not the same as any
other device on the Ethernet or Wireless networks.
RS232 / RS485 Serial Gateway Mode
Serial Gateway Mode
Server
- Module will wait for a connection to be initiated by a remote Client.
Character Timeout
Enter the maximum delay (in msec) between received serial characters before packet
is sent via network.
Packet Size
The number of received bytes that will be buffered before a packet is sent via the
network.
Listen Port (Server)
Server Only. Enter the TCP port number on which the server must listen for incoming
connections. The standard TELNET port is 23.
Serial Gateway Mode
Client -
Module will wait for a connection to be initiated by a remote Server.
Character Timeout
Enter the maximum delay (in msec) between received serial characters before packet
is sent via network.
Packet Size
The number of received bytes that will be buffered before a packet is sent via the
network.
Remote Device Port
(Client)
Client only. Enter the TCP port number of the remote server (i.e. the remote port to
automatically connect to).
Remote Device IP Address
(Client)
Client only. Enter the IP Address of the remote server (i.e. the remote IP Address to
automatically connect to).
Serial Gateway Mode
Multicast
- Allows point to multi-point serial transfer. All members of the group will
receive serial transmissions made by any other member of the Multicast group.
Character Timeout
Enter the maximum delay (in msec) between received serial characters before packet
is sent via network.
Packet Size
The number of received bytes that will be buffered before a packet is sent via the
network.
Multicast Group Port
Enter the UDP port number that all members of the group will use (i.e. all group
members should use the same port number).
Multicast Group IP
Address
Enter a valid Multicast IP Address identifying the group (i.e. all group members
should use the same Multicast Group IP Address). Valid Multicast IP Addresses are in
the range 224.0.1.0 to 238.255.255.255.