XYR301E Wireless Ethernet
User Manual
Page 34
April 2012
Enter the IP address for the XYR301-E into the Internet Explorer Address bar e.g. http://10.10.0.6 which is the IP
address you temporarily configured with the ifconfig command.
Enter the username “
user
” and default password “
user
”.
You should now be connected to the main index page on the modem as per figure 1 above.
From here connect to the Network page and change the Ethernet Interface and Wireless Interface IP addresses to
10.10.0.6. Switch the RUN/SETUP switch back to RUN and press “Save Changes and Reset” button.
Note: As the modem can be setup numerous ways, e.g. Bridge, Router, etc this setup will allow the modem to appear
on the 10.10.0.X network. Any other configuration changes can be done after this initial connection (see the following
sections on configuration)
3.3
Quick Start Configuration
The XYR401 E has a Quick Start Configuration option, which will cover most important parameters that are needed to
get an initial connection. This is the first stage of the module configuration. For most applications, no further
configuration is required. For more advanced applications, the other parameters can be changed via the normal
configuration pages after the Quick Start configuration has been saved.
Select “Quick Start” from the Main Menu and then you need to select the following parameters:
Quick Start Configuration
Operating Mode
Access Point or Client. Bridge operation is assumed - for Router selection, go to the
Network page after Quick Start
Default Gateway
This is the address that the device will use to forward messages to remote hosts that
are not connected to any of the local bridged network (Ethernet or Wireless)
IP Address / Subnet Mask
IP Address and Subnet Mask for your application.
System Address (ESSID)
The system address is a text string 1 to 31 characters in length used to identifies your
system
Radio Encryption
Radio encryption selection - None, WPA-PSK (TKIP), WPA-PSK (AES) or WPA2
– refer to the Network Configuration section if WEP or Enterprise encryption is
required.
WPA Passphrase
128bit Encryption keys are internally generated based on the Passphrase and System
Address (ESSID). The Passphrase must be between 8 and 63 characters in length,
and must be the same for all XYR401-E units in the same system.
The default settings will be shown. If your system is connecting individual devices which are not connected to an
existing Ethernet LAN, then you can use the factory default IP values. If you are connecting to an existing LAN, then
you need to change the IP addresses to match your LAN addresses.
After configuring, select “Save to Flash and Reset”.
Radio Data Rate and Channel will be set to Auto, Radio Transmit Power will be set to maximum and any previous
configuration of unrelated parameters will not be modified, and will still apply.