PART NUMBER 964-0452
1I.B.1516A Page 24
Mar 30/01
23-12-01
Gate Arrays Register Address
Figure 12
Synthesizer D6 Divider Position
Figure 13
A frequency 5kHz higher is input via the data bus, that is to say 15350600 (addr.
4: 1535, addr. 5: 0600). MHz value is added to the constant of the N divider. The
total of 54 (39 + 15) is the N value. The 100kHz value of the frequency is added
to the constant for the A divider. The total of 11 (8 + 3) is the A value.
Value R is 10 for all frequencies. The values for A, N, and R are supplied to syn-
thesizer module D6 in loop 2 with 8 addressed 4-bit words via the lines DOUT0
to DOUT3, AOUT0, AOUT1, AOUT2, and Divider (Ref. Fig. 13).
The value of the frequency from the 10kHz point is added to the constant for
DDS. The total of 270.6kHz (220 + 50.6) is the frequency that is then generated
in the DDS.
The data of a digitized sinusoidal oscillation are stored in EPROM D26. The ad-
dresses for these data are determined in the gate array. The sinusoidal values
are supplied to the D/A converter via latch D24.
Add.
MADR2
MADR1
MADR0
D15. . . . . . . . . . . . . . . . . . . . . . . . . . . .DO
0
0
0
0
–
R03(BCD)
3
R02(BCD)
9
R01(BCD)
8
1
0
0
1
R14(BCD)
2
R13(BCD)
2
R12(HEX)
4
R11(HEX)
C
2
0
1
0
R24(HEX)
4
R23(HEX)
B
R22(HEX)
4
R21(HEX)
0
3
0
1
1
–
R33(HEX)
0
R32(HEX)
0
R31(HEX)
A
4
1
0
0
R44(BCD)
f/10MHz
R43(BCD)
f/1MHz
R42(BCD)
f/100kHz
R41(BCD)
f/10kHz
5
1
0
1
R54(BCD)
f/1kHz
R53(BCD)
f/100Hz
R52(BCD)
f/10Hz
R51(BCD)
f/1Hz
7
1
1
1
VCO preset per Fig. 11
–
–
AOUT2
AOUT1
AOUT0
MADR0
DIVIDER
DOUT3
DOUT2
DOUT1
0
0
0
A
Bit3
Bit2
Bit1
Bit0
0
0
1
A
–
Bit6
Bit5
Bit4
0
1
0
N
Bit3
Bit2
Bit1
Bit0
0
1
1
N
Bit7
Bit6
Bit5
Bit4
1
0
0
N
–
–
Bit9
Bit8
1
0
1
R
Bit3
Bit2
Bit1
Bit0
1
1
0
R
Bit7
Bit6
Bit5
Bit4
1
1
1
R
Bit11
Bit10
Bit9
Bit8
Page 34