Honeywell
COMPONENT MAINTENANCE MANUAL
PART NUMBER 964-0452
I.B.1516A Page 401
Mar 30/01
23-12-01
CLEANING
1. General
Materials for cleaning the assemblies, subassemblies, and parts of the unit are listed in Fig. 401.
NOTE: Equivalent substitutes may be used for all cleaning materials.
Cleaning Materials
Figure 401
WARNING: OBSERVE ALL FIRE PRECAUTIONS WHEN USING FLAMMABLE MATERIALS FOR CLEAN-
ING PURPOSES. USE THESE MATERIALS OUTSIDE, OR IN A VENTILATED BOOTH
EQUIPPED WITH EXPLOSION-PROOF ELECTRICAL EQUIPMENT AND AN EXHAUST FAN
WITH SPARKPROOF BLADES.
WARNING: CLEANING SOLVENTS ARE FLAMMABLE AND TOXIC TO EYES, SKIN, AND RESPIRATORY
TRACT. DO NOT BREATHE VAPORS. USE IN A WELL-VENTILATED AREA FREE FROM
SPARKS, FLAME, AND HOT SURFACES, OR UNDER A VENTILATED HOOD. WEAR
SPLASH GOGGLES, SOLVENT-RESISTANT GLOVES, AND OTHER PROTECTIVE GEAR. IN
CASE OF EYE CONTACT, FLUSH WITH WATER AND SEEK MEDICAL ATTENTION. IN CASE
OF SKIN CONTACT, WASH WITH SOAP AND WATER. CHANGE CLOTHING THAT HAS BE-
COME SATURATED WITH SOLVENT.
WARNING: COMPRESSED AIR USED FOR CLEANING AND DRYING MAY CAUSE AIRBORNE PARTI-
CLES TO ENTER THE EYES. REGULATE PRESSURE TO 30 POUNDS PER SQUARE INCH
OR LESS. WEAR GOGGLES OR FACE SHIELDS TO PROTECT EYES. WARN PERSONS IN
THE IMMEDIATE VICINITY.
2. Transceiver Procedures
CAUTION: ELECTROSTATIC DISCHARGE SENSITIVE (ESDS) DEVICES ARE SUBJECT TO
DAMAGE BY EXCESSIVE LEVELS OF VOLTAGE. REFER TO DOD-HDBK-263 FOR
PROPER HANDLING PROCEDURES.
CAUTION: SMALL COILS, LEADS, AND OTHER DELICATE PARTS CAN BE DAMAGED BY AN AIR
BLAST. KEEP AIR NOZZLE AWAY FROM THESE PARTS.
A. Cleaning the Exterior
(1) Wipe off general contamination on the outside of the housing with a lint-free cloth.
(2) Remove dust from recesses, angles, and connecting jacks with a brush and vacuum
cleaner; if necessary use compressed air.
(3) Clean the housing, and if necessary, the connecting jacks with a nonmetallic brush and
soap solution.
CAUTION: MAKE SURE THAT NO LIQUID (SOAP SOLUTION, ETC.) IS ALLOWED
TO PENETRATE INSIDE THE EQUIPMENT.
(4) Wipe the soap solution off the housing with a damp, lint-free cloth, and rub dry with a dry,
lint-free cloth. Blow recesses, angles, and connectors dry with compressed air.
MATERIALS
SPECIFICATION/SOURCE
TT-I-435, Grade A, commercially available
Brush, Soft-Bristle, Nonmetallic
Cloth,Cotton, Lint-free
Detergent, Low-Suds
Water, Soft
Materials are obtainable from any
commercial source.