Maintenance
VXP System Maintenance Manual 4-21
A004
Recoverable Hardware Failure.
Internally recoverable hardware problems have occurred in the
VXP
AU. If these
problems continue to occur through many power cycles, or if the
VXP
operates
in an unpredictable manner, the system may be operating under marginal
conditions and could fail in the future. Maintain copies of the downloaded Fault
Logs and contact Chadwick-Helmuth.
A005
Bad Upload File Format or File Corrupted.
Reload the application or setup configuration file. If problem persists, the
uploaded file is bad or corrupted. Correct upload file format or contact
Chadwick-Helmuth.
A006
Credit card memory system (PCMCIA card) has failed.
System will continue to run, but Credit Card cannot be used for upload or
download of program files. Use the DU communications interface to transfer
files until Chadwick-Helmuth can be contacted to resolve the problem. Note:
PCMCIA slot not accessible in ground support configuration.
A007
Calibration Error.
Analog signal input function is out of calibration. System can continue to be used
but vibration and balance readings may not be accurate. Save Fault Log and
contact Chadwick-Helmuth as soon as possible.
A008
Vibration Sensor Failure.
A vibration sensor has failed. Channel number of failed sensor is obtained from
the Fault Log. First, check connections to sensor. Next, replace failed sensor with
a known good sensor. If problem moves with the failed sensor, then replace the
sensor. If the problem does not move with the sensor, then the sensor cable is the
probable cause.
A009
No Magnetic Pickup.
No magnetic pickup signal is present. Channel number of pickup is obtained
from fault log. The rotors must be turning for the current operation. If not, the
operation must be tried when the rotors are turning. If the rotors are turning, then
remove and replace the affected magnetic pickup. If the problem persists then
check the cabling to the pickup.
A010
RPM Out Of Range.
RPM from magnetic pickup is out of range. The current operation must be
performed with the rotors turning at a specified speed. Check aircraft instruments
for correct speed (e.g. 100% Nr) and correct rotor RPM as necessary. If
instruments indicate correct speed, then problem is probably an incorrect gap
setting between the interrupter and the mag pickup. If the gap is OK, then check
both the mag pickup and its cabling.
Table 4-11. Action Codes (Continued)
ACTION
NUMBER
EXPLANATION
Summary of Contents for VXP
Page 4: ...iv Honeywell ...
Page 8: ...viii Honeywell ...
Page 10: ...x Honeywell ...
Page 15: ...Introduction VXP System Maintenance Manual 1 5 Figure 1 7 System Accessories ...
Page 16: ...1 6 Honeywell Introduction Figure 1 8 System Cables ...
Page 28: ...1 18 Honeywell Introduction ...
Page 36: ...2 8 Honeywell Preparation for Use ...
Page 68: ...4 24 Honeywell Maintenance ...
Page 86: ...7 2 Chadwick Helmuth Company Inc Cable Parts List Figure 7 1 Photocell Cable P N 902 10185 ...
Page 90: ...7 6 Chadwick Helmuth Company Inc Cable Parts List Figure 7 3 DC Power Cable P N 902 10813 ...
Page 92: ...7 8 Chadwick Helmuth Company Inc Cable Parts List Figure 7 4 Velocimeter Cable P N 902 11210 ...
Page 94: ...7 10 Chadwick Helmuth Company Inc Cable Parts List Figure 7 5 FasTrak Cable P N 902 13279 ...
Page 100: ...7 16 Chadwick Helmuth Company Inc Cable Parts List ...
Page 102: ...8 2 Honeywell Wiring Diagram ...
Page 103: ......
Page 104: ......
Page 105: ......