1-10 Honeywell
Introduction
Interfaces
Magnetic Pickup/Photocell: 4
Photoprobe, High Speed: 2
Velocimeter: 16
Accelerometer (ICP): 26
Accelerometer (HTA): 6
Discrete Signal I/O: 6
Strobex: 1
Fastrak: 2
PCMCIA Type 2 Card Slot (on-board
configuration): 1
USB: 1
High Speed Tach: 4
Balance
Amplitude Accuracy
±2%
Phase Resolution
1 degree
Frequency Range
180 to 60,000 rpm
Harmonics
1 to 5
Simultaneous Channels
4 vibration
1 azimuth
1 FasTrak
Vector Operations
(A + B)/2, (A - B)/2
Spectrum
Frequency Ranges
0 - 20 Hz to 0 - 75 KHz
Frequency Resolution
400 to 51,200 lines
Window Types
Flat-top, Hanning, Kaiser-Bessel, Uniform
Simultaneous Channels
4 vibration
1 azimuth
Dynamic Range
> 90 dB
Averaging
Linear, Peak hold
Amplitude Accuracy
±2%
Table 1-3. Acquisition Unit Leading Particulars (Continued)
Parameter
Characteristic
Summary of Contents for VXP
Page 4: ...iv Honeywell ...
Page 8: ...viii Honeywell ...
Page 10: ...x Honeywell ...
Page 15: ...Introduction VXP System Maintenance Manual 1 5 Figure 1 7 System Accessories ...
Page 16: ...1 6 Honeywell Introduction Figure 1 8 System Cables ...
Page 28: ...1 18 Honeywell Introduction ...
Page 36: ...2 8 Honeywell Preparation for Use ...
Page 68: ...4 24 Honeywell Maintenance ...
Page 86: ...7 2 Chadwick Helmuth Company Inc Cable Parts List Figure 7 1 Photocell Cable P N 902 10185 ...
Page 90: ...7 6 Chadwick Helmuth Company Inc Cable Parts List Figure 7 3 DC Power Cable P N 902 10813 ...
Page 92: ...7 8 Chadwick Helmuth Company Inc Cable Parts List Figure 7 4 Velocimeter Cable P N 902 11210 ...
Page 94: ...7 10 Chadwick Helmuth Company Inc Cable Parts List Figure 7 5 FasTrak Cable P N 902 13279 ...
Page 100: ...7 16 Chadwick Helmuth Company Inc Cable Parts List ...
Page 102: ...8 2 Honeywell Wiring Diagram ...
Page 103: ......
Page 104: ......
Page 105: ......