4-12 Honeywell
Maintenance
•
Enter 900 in the
BAL RPM:
window by highlighting the existing entry on the
display with the stylus, and then typing in the number using the keypad.
•
Select MANUAL STOP in the pull down window.
11.
Click on the
Start
button.
12.
After a few seconds, the RPM in the upper left corner of the Bal Meas Only window
should read approximately 900 RPM.
NOTE:
If you cannot adjust the distance or alignment to obtain 900 RPM, there may be a
problem with the FasTrak. Return it to Chadwick-Helmuth for adjustment.
13.
Click on the
Stop
button to end the test.
Night Mode Test
This test should be run in a room that can be darkened to simulate night operations.
1.
Replace the FasTrak cable (13279) with the test cable shown in Table 4-1 (P/N
12700). Set the switch on the test cable to “DAY MODE” operation.
2.
Keep all settings on the calibrator and
Balance Measurement Only
screen as they
were for the previous FasTrak test. See step 9.
3.
Click on the
Start
button.
4.
To simulate night operation, turn off all lights in room, or enclose the test setup
within a darkened enclosure, such as a large box. The RPM should drop to zero when
the area is dark enough.
5.
Set the switch on the 12700 test cable to “NIGHT MODE.”
6.
After a few seconds, the RPM should rise again to approximately 900.
7.
Click on the
Stop
button to end the test.
4.3.7.1 Special Overlays
The figure below can be used to construct the special overlays needed for the FasTrak test. Copy
the overlay, and cut the circle to fit the strobe disk of the Model 11A Calibrator.
Figure 4-7. Special Overlay
Summary of Contents for VXP
Page 4: ...iv Honeywell ...
Page 8: ...viii Honeywell ...
Page 10: ...x Honeywell ...
Page 15: ...Introduction VXP System Maintenance Manual 1 5 Figure 1 7 System Accessories ...
Page 16: ...1 6 Honeywell Introduction Figure 1 8 System Cables ...
Page 28: ...1 18 Honeywell Introduction ...
Page 36: ...2 8 Honeywell Preparation for Use ...
Page 68: ...4 24 Honeywell Maintenance ...
Page 86: ...7 2 Chadwick Helmuth Company Inc Cable Parts List Figure 7 1 Photocell Cable P N 902 10185 ...
Page 90: ...7 6 Chadwick Helmuth Company Inc Cable Parts List Figure 7 3 DC Power Cable P N 902 10813 ...
Page 92: ...7 8 Chadwick Helmuth Company Inc Cable Parts List Figure 7 4 Velocimeter Cable P N 902 11210 ...
Page 94: ...7 10 Chadwick Helmuth Company Inc Cable Parts List Figure 7 5 FasTrak Cable P N 902 13279 ...
Page 100: ...7 16 Chadwick Helmuth Company Inc Cable Parts List ...
Page 102: ...8 2 Honeywell Wiring Diagram ...
Page 103: ......
Page 104: ......
Page 105: ......