Maintenance
VXP System Maintenance Manual
4-11
4.
Verify that there is a small strip of reflective tape on the shaft of the calibrator
underneath the disk.
5.
Set CAM RATE (RPM) switch to 900.
6.
Turn on calibrator and adjust pot next to 900 CAM RATE switch position until 2
nd
ring from outside on rotor disk appears frozen in place under 60 Hz light.
1
7.
Using the DU and Display Program, click on the
Measurements Only
button in the
Select Procedure menu of the Application Program. Refer to Section 3.2.1 for
detailed instructions on manual operation.
8.
In the
Measurements Only
menu, click on the
Bal Meas Only
button.
9.
In the
Bal Meas Only
menu (Figure 4-3), enter the following settings:
•
Select PHOTOPROBE in the
AZ CH:
pull down window.
•
Select VELO 1 in the
VIB CH:
pull down window.
•
Enter 900 in the
BAL RPM:
window by highlighting the existing entry on the
display with the stylus, and then typing in the number using the keypad.
•
Select 1 in the
N PER REV
pull down window.
•
Select AUTO STOP in the pull down window.
10.
Click on the
Start
button.
11.
Verify that the correct RPM is displayed in the upper left corner of the Bal Meas
Only window.
4.3.7 FasTrak Test
Before doing the FasTrak test, make sure you have the special overlay for the calibrator disk. See
paragraph 4.3.7.1 and Figure 4-7 for samples that can be copied or recreated.
NOTE:
This test should be performed in a well-lit room.
1.
Assemble the test set-up as shown in Figure 4-1 using the appropriate sensors and
cables.
2.
Place calibrator on its back on a flat surface.
3.
Place FasTrak on its side with the pin connector facing up. The FasTrak window
should be facing the calibrator approximately six inches away.
4.
Set CAM RATE (RPM) switch to 900.
5.
Turn on calibrator and adjust pot next to 900 CAM RATE switch position until 2
nd
ring from outside on rotor disk appears frozen in place under 60 Hz light.
1
6.
Tape the overlay you made from Figure 4-7 onto the rotor disk to simulate blade
passing.
7.
Plug the FasTrak cable (P/N 13279) into the “A” connector on AU and into FasTrak
Optical Sensor.
8.
Using the DU and Display Program, click on the
Measurements Only
button in the
Select Procedure menu of the Application Program. Refer to Section 3.2.1 for
detailed instructions on manual operation.
9.
In the
Measurements Only
menu, click on the
Bal Meas Only
button.
10.
In the
Bal Meas Only
menu (Figure 4-3), enter the following settings:
•
Select AZIMUTH 1 in the
AZ CH:
pull down window.
Summary of Contents for VXP
Page 4: ...iv Honeywell ...
Page 8: ...viii Honeywell ...
Page 10: ...x Honeywell ...
Page 15: ...Introduction VXP System Maintenance Manual 1 5 Figure 1 7 System Accessories ...
Page 16: ...1 6 Honeywell Introduction Figure 1 8 System Cables ...
Page 28: ...1 18 Honeywell Introduction ...
Page 36: ...2 8 Honeywell Preparation for Use ...
Page 68: ...4 24 Honeywell Maintenance ...
Page 86: ...7 2 Chadwick Helmuth Company Inc Cable Parts List Figure 7 1 Photocell Cable P N 902 10185 ...
Page 90: ...7 6 Chadwick Helmuth Company Inc Cable Parts List Figure 7 3 DC Power Cable P N 902 10813 ...
Page 92: ...7 8 Chadwick Helmuth Company Inc Cable Parts List Figure 7 4 Velocimeter Cable P N 902 11210 ...
Page 94: ...7 10 Chadwick Helmuth Company Inc Cable Parts List Figure 7 5 FasTrak Cable P N 902 13279 ...
Page 100: ...7 16 Chadwick Helmuth Company Inc Cable Parts List ...
Page 102: ...8 2 Honeywell Wiring Diagram ...
Page 103: ......
Page 104: ......
Page 105: ......