2.2.2.2 AU Software Loading Procedure
The group of software programs that run on the AU is called the Application Program (AP), and
consists of the VXP Operational Program (OP), SmartCharts, balance models, data collection
routes, and other configuration files. Each time the VXP is used on a new aircraft type, an AP
specific to that aircraft must be loaded into the AU. Each AP has a unique name and part number.
Consult Chadwick-Helmuth for information on which AP is required for a specific aircraft.
The APs are provided on an 8M/16M CompactFlash Card, and must be loaded into the AU via the
CompactFlash Card Reader or the Zio! Reader in the PCMCIA slot. The APs may also be stored
on the hard disk drive of the DU for easier loading in the future. The AU is generally provided
with an AP installed. However, if a new or different AP is desired, it may be loaded into the AU as
follows:
1.
Connect the system cables as detailed in section 2.2.1.
2.
Apply power to the AU and DU.
3.
Insert the VXP Application software 8M/16M CompactFlash card containing the
desired AP into the CompactFlash Card Reader.
4.
Insert the 8M/16M CompactFlash Card and Reader into the PCMCIA slot on the
DU.
5.
Start the DP by double clicking on (or touching twice in rapid succession) the VXP
icon
on the DU desktop. The dialog box shown in Figure 2-1 will appear.
6.
Select
Load Application
from the start up menu (Figure 2-1) and click on the
OK
button or press the Enter key.
Figure 2-1. Connect to AU-Load Application Dialog Box
7.
In the “Look-in” pull down menu, select the
(D:)
drive (or appropriate location).
8.
Select the desired AP file (*.app) and click on the
Open
button or hit the Enter key
to load the application.
NOTE:
To load an application using the Operating Program (OP), check the Override
Fast Upload check box before clicking the Open button. The upload may be
slower if this option is checked.
9.
In the
VXP about to load application
dialog box, click on either Yes or No to save
the application to the DU hard drive. This will eliminate having to reload the
application from the PCMCIA CompactFlash Card Reader.
NOTE:
Applications are saved in the directory C:\VXP\Apps.
10.
Upon completion, the DU will connect to the AU and the Select Procedure window
will appear. See Chapter 3.
Summary of Contents for VXP
Page 4: ...iv Honeywell ...
Page 8: ...viii Honeywell ...
Page 10: ...x Honeywell ...
Page 15: ...Introduction VXP System Maintenance Manual 1 5 Figure 1 7 System Accessories ...
Page 16: ...1 6 Honeywell Introduction Figure 1 8 System Cables ...
Page 28: ...1 18 Honeywell Introduction ...
Page 36: ...2 8 Honeywell Preparation for Use ...
Page 68: ...4 24 Honeywell Maintenance ...
Page 86: ...7 2 Chadwick Helmuth Company Inc Cable Parts List Figure 7 1 Photocell Cable P N 902 10185 ...
Page 90: ...7 6 Chadwick Helmuth Company Inc Cable Parts List Figure 7 3 DC Power Cable P N 902 10813 ...
Page 92: ...7 8 Chadwick Helmuth Company Inc Cable Parts List Figure 7 4 Velocimeter Cable P N 902 11210 ...
Page 94: ...7 10 Chadwick Helmuth Company Inc Cable Parts List Figure 7 5 FasTrak Cable P N 902 13279 ...
Page 100: ...7 16 Chadwick Helmuth Company Inc Cable Parts List ...
Page 102: ...8 2 Honeywell Wiring Diagram ...
Page 103: ......
Page 104: ......
Page 105: ......