background image

1 - 5

Connecting with RS485

A scanner or cordless base can be connected for an IBM POS terminal 
interface.

1.

Connect the appropriate interface cable to the device, then to the com-
puter.

2.

Turn the terminal/computer power back on.  The scanner beeps.

3.

Verify the scanner or cordless base operation by scanning a bar code 
from the 

Sample Symbols

 in the back of this manual.  The scanner 

beeps once.

For further RS485 settings, refer to 

RS485

, page 2-2

Summary of Contents for Voyager 1400g Series

Page 1: ... Voyager 1400g Series Area Imaging Scanner User s Guide ...

Page 2: ...formance or use of this material HII disclaims all responsibility for the selection and use of software and or hardware to achieve intended results This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied repro duced or translated into another language without the prior written consent of HII 2012 2014 Honeywe...

Page 3: ...ouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio or television technician for help If necessary the user should con...

Page 4: ...rme NMB 003 du Canada Son fonctionnement est assujetti aux conditions suivantes 1 Cet appareil ne doit pas causer de brouillage préjudiciable 2 Cet appareil doit pouvoir accepter tout brouillage reçu y compris le brouillage pouvant causer un fonctionnement indésirable C UL Statement C UL listed CSA C22 2 No 60950 1 07 2nd Edition Europe The CE marking indicates compliance with the following direct...

Page 5: ...t meets Korean agency approval for Class B equipment 이 기기는 가정용 B급 전자파적합기기로서 주로 가정에서 사용 하는 것을 목적으로 하며 모든 지역에서 사용할 수 있습니다 Taiwan If the following label is attached to your product the product meets Taiwan agency approval BSMI Standard CNS13438 CNS14336 1 依據標準 CNS13438 CNS14336 1 International LED Safety Statement The LED has been tested and classified as EXEMPT RISK GROUP to the standard IEC 62471 2...

Page 6: ... www hsmpats com Solids and Water Protection The Voyager 1400g has a rating of IP42 immunity of foreign particles and drip ping water Warning To reduce the possibility of heat related injuries avoid touching sec tions of the scanner that feel warm ...

Page 7: ...Required Safety Labels Compliance Markings information Part Number and Serial Number information Compliance Markings information ...

Page 8: ......

Page 9: ... Interface Introduction 2 1 Programming the Interface Plug and Play 2 1 Keyboard Wedge 2 1 Laptop Direct Connect 2 1 RS232 Serial Port 2 2 RS485 2 2 RS485 Packet Mode 2 3 USB IBM SurePos 2 4 USB PC or Macintosh Keyboard 2 4 USB HID 2 5 USB Serial 2 5 CTS RTS Emulation 2 5 ACK NAK Mode 2 5 Verifone Ruby Terminal Default Settings 2 6 Gilbarco Terminal Default Settings 2 6 Honeywell Bioptic Aux Port ...

Page 10: ...c Communication 2 24 Scanner Bioptic Packet Mode 2 24 Scanner Bioptic ACK NAK Mode 2 25 Scanner Bioptic ACK NAK Timeout 2 25 Chapter 3 Input Output Settings Power Up Beeper 3 1 Beep on BEL Character 3 1 Trigger Click 3 1 Good Read and Error Indicators 3 2 Beeper Good Read 3 2 Beeper Volume Good Read 3 2 Beeper Pitch Good Read 3 3 Beeper Pitch Error 3 3 Beeper Duration Good Read 3 3 LED Good Read 3...

Page 11: ...Data Editing Prefix Suffix Overview 4 1 To Add a Prefix or Suffix 4 1 To Clear One or All Prefixes or Suffixes 4 2 To Add a Carriage Return Suffix to All Symbologies 4 3 Prefix Selections 4 3 Suffix Selections 4 4 Function Code Transmit 4 4 Intercharacter Interfunction and Intermessage Delays 4 4 Intercharacter Delay 4 5 User Specified Intercharacter Delay 4 5 Interfunction Delay 4 6 Intermessage ...

Page 12: ... Pharmaceutical PARAF 6 8 Full ASCII 6 9 Code 39 Code Page 6 9 Interleaved 2 of 5 6 10 NEC 2 of 5 6 12 Code 93 6 14 Code 93 Code Page 6 15 Straight 2 of 5 Industrial three bar start stop 6 16 Straight 2 of 5 IATA two bar start stop 6 17 Matrix 2 of 5 6 18 Code 11 6 19 Code 128 6 20 ISBT 128 Concatenation 6 20 Code 128 Code Page 6 22 GS1 128 6 23 Telepen 6 24 UPC A 6 25 UPC A EAN 13 with Extended C...

Page 13: ... GS1 Emulation 6 46 TCIF Linked Code 39 TLC39 6 47 QR Code 6 48 QR Code Page 6 49 Data Matrix 6 50 Data Matrix Code Page 6 51 MaxiCode 6 52 Aztec Code 6 53 Aztec Code Page 6 54 Chinese Sensible Han Xin Code 6 55 Postal Codes Linear 6 55 China Post Hong Kong 2 of 5 6 55 Korea Post 6 57 Postal Codes 2D 6 58 Single 2D Postal Codes 6 58 Combination 2D Postal Codes 6 59 Chapter 7 Interface Keys Keyboar...

Page 14: ...y Defaults 8 4 Chapter 9 Serial Programming Commands Conventions 9 1 Menu Command Syntax 9 1 Query Commands 9 2 Responses 9 2 Resetting the Custom Defaults 9 4 Menu Commands 9 5 Chapter 10 Product Specifications Voyager 1400g Scanner Product Specifications 10 1 Standard Connector Pinouts 10 3 Keyboard Wedge 10 3 Serial Output 10 3 USB 10 4 RS485 Output 10 4 Chapter 11 Maintenance Repairs 11 1 Main...

Page 15: ... Chapter 12 Customer Support Appendix A Reference Charts Symbology Charts A 1 Linear Symbologies A 1 2D Symbologies A 3 Postal Symbologies A 3 ASCII Conversion Chart Code Page 1252 A 4 Lower ASCII Reference Table A 5 ISO 2022 ISO 646 Character Replacements A 10 Unicode Key Maps A 13 ...

Page 16: ...viii ...

Page 17: ...ll bar code scanners are factory programmed for the most common terminal and communications settings If you need to change these settings programming is accomplished by scanning the bar codes in this guide An asterisk next to an option indicates the default setting Unpacking Your Device After you open the shipping carton containing the product take the following steps Check for damage during shipm...

Page 18: ...efer to USB Application Note available at www honeywellaidc com Connecting with Keyboard Wedge A scanner can be connected between the keyboard and PC as a keyboard wedge where the scanner provides data output that is similar to keyboard entries The following is an example of a keyboard wedge connection 1 Turn off power and disconnect the keyboard cable from the back of the terminal computer 2 Conn...

Page 19: ...ify the scanner operation by scanning a bar code from the Sample Symbols in the back of this manual The scanner beeps once The unit defaults to an IBM PC AT and compatibles keyboard wedge inter face with a USA keyboard A carriage return CR suffix is added to bar code data ...

Page 20: ...anner to work properly you must have the correct cable for your type of terminal computer 3 Plug the serial connector into the serial port on your computer Tighten the two screws to secure the connector to the port 4 Once the scanner has been fully connected power up the computer This interface programs 115 200 baud 8 data bits no parity and 1 stop bit ...

Page 21: ...appropriate interface cable to the device then to the com puter 2 Turn the terminal computer power back on The scanner beeps 3 Verify the scanner or cordless base operation by scanning a bar code from the Sample Symbols in the back of this manual The scanner beeps once For further RS485 settings refer to RS485 page 2 2 ...

Page 22: ...rther from the unit To read single or multiple symbols on a page or on an object hold the scanner at an appro priate distance from the target press the button and center the aiming beam or pattern on the symbol If the code being scanned is highly reflective e g lami nated it may be necessary to tilt the code up 15 to 18 to prevent unwanted reflection Menu Bar Code Security Settings Honeywell scann...

Page 23: ...usly saved the setting for Beeper Volume at Low to your custom defaults and decide you want the beeper volume set to High just scan the Set Custom Defaults bar code then scan the Beeper Volume High menu code and then Save Custom Defaults The rest of the custom defaults will remain but the beeper volume setting will be updated Resetting the Custom Defaults If you want the custom default settings re...

Page 24: ...1 8 ...

Page 25: ...rammed for an IBM PC AT and compatibles key board wedge interface with a USA keyboard scan the bar code below Key board wedge is the default interface Note The following bar code also programs a carriage return CR suffix Laptop Direct Connect For most laptops scanning the Laptop Direct Connect bar code allows opera tion of the scanner in parallel with the integral keyboard The following Laptop Dir...

Page 26: ...i cated below It also changes the trigger mode to manual RS485 Scan one of the following Plug and Play codes to program the scanner for an IBM POS terminal interface Note After scanning one of these codes you must power cycle the cash register Option Setting Baud Rate 115 200 bps Data Format 8 data bits no parity bit 1 stop bit RS232 Interface IBM Port 5B Interface IBM Port 9B HHBCR 1 Interface IB...

Page 27: ... Packet Mode On bar code below Scan the Packet Mode Off bar code if you want large bar code data to be sent to the host in a single chunk Default Packet Mode Off RS485 Packet Length If you are using Packet mode you can specify the size of the data packet that is sent to the host Scan the Packet Length bar code then then the packet size from 20 256 from the Programming Chart inside the back cover o...

Page 28: ...suffixes for each symbology USB PC or Macintosh Keyboard Scan one of the following codes to program the scanner for USB PC Keyboard or USB Macintosh Keyboard Scanning these codes also adds a CR and LF Symbology Suffix Symbology Suffix EAN 8 0C Code 39 00 0A 0B EAN 13 16 Interleaved 2 of 5 00 0D 0B UPC A 0D Code 128 00 18 0B UPC E 0A Code 39 00 0A 0B USB IBM SurePos USB Handheld Scanner Interface U...

Page 29: ...need to download a driver from the Honeywell website www honeywellaidc com The driver will use the next available COM Port number Apple Macintosh comput ers recognize the scanner as a USB CDC class device and automatically uses a class driver Note No extra configuration e g baud rate is necessary CTS RTS Emulation ACK NAK Mode USB HID Bar Code Scanner USB Serial CTS RTS Emulation On CTS RTS Emulat...

Page 30: ...lowing prefixes for each symbology Gilbarco Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Gilbarco terminal This bar code sets the baud rate to 2400 bps and the data format to 7 data bits even parity 2 stop bits It also also adds a carriage return CR suffix and programs the following prefixes for each symbology Symbology Prefix UPC A A UPC E A EAN 8 F...

Page 31: ...scanner auxiliary port configuration This bar code sets the baud rate to 9600 bps and the data format to 8 data bits no parity 1 stop bit NCR Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for an NCR biop tic scanner auxiliary port configuration The following prefixes are programmed for each symbology Symbology Prefix Symbology Prefix UPC A A Interleave...

Page 32: ...etle Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Wincor Nix dorf Beetle terminal The following prefixes are programmed for each symbol ogy Symbology Prefix Symbology Prefix Code 128 K EAN 13 A Code 93 L GS1 128 P Codabar N Interleaved 2 of 5 I UPC A A0 Plessey O UPC E C Straight 2 of 5 IATA H EAN 8 B All other bar codes M NCR Bioptic Settings Wincor...

Page 33: ... or language As a general rule the following characters are sup ported but need special care for countries other than the United States United States United States Dvorak left United States International Albania Azeri Cyrillic Azeri Latin Belarus Belgium United States Dvorak United States Dvorak right Bosnia Brazil ...

Page 34: ...eyboard Country continued Bulgaria Latin Canada French Canada Multilingual Croatia Czech Czech Programmers Czech QWERTY Czech QWERTZ Bulgaria Cyrillic Canada French legacy Brazil MS Denmark Dutch Netherlands ...

Page 35: ...2 11 Keyboard Country continued Finland Gaelic Germany Greek Greek 220 Latin Greek 220 Greek 319 Latin Greek 319 Faeroese France Estonia Greek Latin Greek MS ...

Page 36: ...2 12 Keyboard Country continued Italian 142 Hungarian 101 key Iceland Irish Italy Japan ASCII Kazakh Kyrgyz Cyrillic Hebrew Hungary Greek Polytonic Latin America Latvia ...

Page 37: ...2 13 Keyboard Country continued Lithuania IBM Malta Mongolian Cyrillic Norway Poland Polish 214 Polish Programmers Portugal Lithuania Macedonia Latvia QWERTY Romania Russia ...

Page 38: ...2 14 Keyboard Country continued SCS Serbia Latin Slovakia Slovakia QWERTY Slovakia QWERTZ Slovenia Spain Spanish variation Russian Typewriter Serbia Cyrillic Russian MS Sweden Switzerland French ...

Page 39: ...If you have used Keyboard Conversion settings they will override any of the following Key board Style settings Default Regular Turkey F Ukrainian United Kingdom United Stated Dvorak right United States Dvorak left United States Dvorak United States International Uzbek Cyrillic Tatar Turkey Q Switzerland German ...

Page 40: ...e tracks and reflects if you have Caps Lock on or off This selection can only be used with systems that have an LED that notes the Caps Lock sta tus AT keyboards Autocaps via NumLock bar code should be scanned in countries e g Ger many France where the Caps Lock key cannot be used to toggle Caps Lock The NumLock option works similarly to the regular Autocaps but uses the Num Lock key to retrieve t...

Page 41: ...e Keyboard Style selections Note If your interface is a keyboard wedge first scan the menu code for Automatic Caps Lock page 2 16 Otherwise your output may not be as expected Default Keyboard Conversion Off Control Character Output This selection sends a text string instead of a control character For example when the control character for a carriage return is expected the output would display CR i...

Page 42: ...s not support all keyboard country codes New users should use the Windows mode Refer to Keyboard Function Relationships page 7 1 for CTRL ASCII Values Windows Mode Prefix Suffix Off The scanner sends key combinations for ASCII control characters for values 00 1F but it does not translate any prefix or suffix information Default Control ASCII Mode Off Control Character Output On Control Character O...

Page 43: ...nds numeric characters as if entered from a numeric keypad Default Off Automatic Direct Connect Mode This selection can be used if you have an IBM AT style terminal and the system is dropping characters Default Off Turbo Mode On Turbo Mode Off Numeric Keypad Mode On Numeric Keypad Mode Off Automatic Direct Connect Mode On Automatic Direct Connect Mode Off ...

Page 44: ...ate Baud Rate sends the data from the scanner to the terminal at the specified rate The host terminal must be set for the same baud rate as the scanner Default 9600 300 2400 600 1200 4800 38400 9600 19200 115 200 57 600 ...

Page 45: ...cations that require use of the full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 Parity provides a means of checking character bit patterns for validity Default None 7 Data 1 Stop Parity Even 7 Data 1 Stop Parity None 7 Data 1 Stop Parity Odd 7 Data 2 Stop Parity Even 7 Data 2 Stop Parity None 8 Data 1 Stop Parity None 8 Data 1 Stop Parity ...

Page 46: ...rol of data transmission from the scanner using software commands from the host device When RTS CTS is turned Off no data flow control is used Flow Control No Timeout The scanner asserts RTS when it has data to send and will wait indefinitely for CTS to be asserted by the host Two Direction Flow Control The scanner asserts RTS when it is OK for the host to transmit The host asserts CTS when it is ...

Page 47: ...a XON XOFF On or to stop sending data XON XOFF Off When the host sends the XOFF character DC3 hex 13 to the scanner data transmission stops To resume transmission the host sends the XON character DC1 hex 11 Data transmission continues where it left off when XOFF was sent Default XON XOFF Off ACK NAK After transmitting data the scanner waits for an ACK character hex 06 or a NAK character hex 15 res...

Page 48: ...oneywell scanners and bioptic scanners Note The scanner s baud rate must be set to 38400 and the RS232 timeout must be set to 3000 in order to communicate with a bioptic scanner See RS232 Baud Rate on page 2 20 and RS232 Timeout on page 2 23 for further information Scanner Bioptic Packet Mode Packet Mode On must be scanned to set the scanner s format so it is com patible with a bioptic scanner Def...

Page 49: ...ow long the scanner will wait for a response Default Bioptic ACK NAK Off Scanner Bioptic ACK NAK Timeout This allows you to set the length in milliseconds for a timeout for a bioptic scanner s ACK NAK response Scan the bar code below then set the time out from 1 30 000 milliseconds by scanning digits from the inside back cover then scanning Save Default 5100 Bioptic ACK NAK Off Bioptic ACK NAK On ...

Page 50: ...2 26 ...

Page 51: ...BEL On bar code below the scanner will beep every time a BEL character is received from the host Default Beep on BEL Off Trigger Click To hear an audible click every time the scanner button is pressed scan the Trig ger Click On bar code below Scan the Trigger Click Off code if you don t wish to hear the click This feature has no effect on serial or automatic trigger ing Default Trigger Click Off P...

Page 52: ...is option off only turns off the beeper response to a good read indication All error and menu beeps are still audible Default Beeper Good Read On Beeper Volume Good Read The beeper volume codes modify the volume of the beep the scanner emits on a good read Default High Beeper Good Read On Beeper Good Read Off High Medium Off Low ...

Page 53: ...per pitch codes modify the pitch frequency of the sound the scan ner emits when there is a bad read or error Default Razz Beeper Duration Good Read The beeper duration codes modify the length of the beep the scanner emits on a good read Default Normal Low 1600 Hz Medium 2400 Hz High 4200 Hz Razz 250 Hz Medium 3250 Hz High 4200 Hz Normal Beep Short Beep Short Beep ...

Page 54: ...r code below and then scan a digit 1 9 bar code and the Save bar code on the Programming Chart inside the back cover of this manual Default 1 Number of Beeps Error The number of beeps and LED flashes emitted by the scanner for a bad read or error can be programmed from 1 9 For example if you program this option to have five error beeps there will be five error beeps and five LED flashes in respons...

Page 55: ...ay scan the bar code below then set the delay from 0 30 000 milliseconds by scanning digits from the inside back cover then scanning Save Manual Trigger Mode When in manual trigger mode the scanner scans until a bar code is read or until the button is released Default Manual Trigger Normal No Delay Short Delay 500 ms Medium Delay 1 000 ms Long Delay 1 500 ms User Specified Good Read Delay Manual T...

Page 56: ...The lower the ambient light in the room the brighter the LEDs need to be so the scanner can see the bar codes In Stand Sensor Mode This feature senses when the scanner is removed from the stand and tells it to begin manual triggering When Sensor On is enabled the scanner defaults to Presentation Mode when it is in the stand and to Manual Trigger Mode when it is removed from the stand Default Senso...

Page 57: ...ower Idle Illumination settings and there is not enough ambient light the scanner may have difficulty detecting when a bar code is presented to it If the scanner has difficulty waking up to read bar codes you may need to set the Idle Illumination to a brighter setting Presentation Sensitivity Presentation Sensitivity is a numeric range that increases or decreases the scanner s reaction time to bar...

Page 58: ...ation Centering On the scanner only reads codes that pass through the centering window you specify using the Top of Presentation Centering Window Bottom of Presentation Centering Window Left and Right of Presentation Centering Window bar codes In the example below the white box is the centering window The centering window has been set to 20 left 30 right 8 top and 25 bottom Since Bar Code 1 passes...

Page 59: ...On the button is used to allow decoded data to be transmit ted to the host system The scanner remains on scanning and decoding bar codes but the bar code data is not transmitted until the button is pressed When CodeGate is Off bar code data is transmitted when it is decoded Default CodeGate Off Out of Stand Left of Presentation Centering Window Top of Presentation Centering Window Right of Present...

Page 60: ... mode You can set the time the scanner should remain in manual trigger mode by setting the Hands Free Time Out Once the time out value is reached if there have been no further button presses the scanner reverts to the original hands free mode Scan the Hands Free Time Out bar code then scan the time out duration from 0 300 000 milliseconds from the inside back cover and Save Default 5 000 ms Reread...

Page 61: ...held it reads only those bar codes intended by the user For instance if multiple codes are placed closely together centering will insure that only the desired codes are read Note To adjust centering when the scanner is in the stand see Presentation Centering page 3 8 If a bar code is not touched by a predefined window it will not be decoded or output by the scanner If centering is turned on by sca...

Page 62: ...s through the centering window it will be read Bar Code 2 does not pass through the centering window so it will not be read Note A bar code needs only to be touched by the centering window in order to be read It does not need to pass completely through the centering window 0 Bar Code 1 Bar Code 2 10 20 30 40 50 60 70 80 90 100 100 90 80 70 60 50 40 30 20 10 0 ...

Page 63: ... On the scanner notifies you if a code cannot be read If using an EZConfig Scanning Tool Scan Data Window see page 8 2 an NR appears when a code cannot be read If No Read is turned Off the NR will not appear Default Off If you want a different notation than NR for example Error or Bad Code you can edit the output message see Data Formatting beginning on page 5 1 The hex code for the No Read symbol...

Page 64: ...ed bar codes Scan Video Reverse and Standard Bar Codes to read both types of codes Note After scanning Video Reverse Only menu bar codes cannot be read You must scan Video Reverse Off or Video Reverse and Standard Bar Codes in order to read menu bar codes Note Images downloaded from the unit are not reversed This is a setting for decoding only Video Reverse Only Video Reverse and Standard Bar Code...

Page 65: ...or upside down Use the working orientation settings if your direction sensitive codes will not usually be presented upright to the scanner Default Upright Default Upright Upright Vertical Top to Bottom Rotate CW 90 Upside Down Vertical Bottom to Top Rotate CCW 90 Upright Upside Down Vertical Top to Bottom Vertical Bottom to Top ...

Page 66: ...3 16 ...

Page 67: ...ault suffix None A prefix or suffix may be added or cleared from one symbology or all symbologies You can add any prefix or suffix from the ASCII Conversion Chart Code Page 1252 beginning on page A 4 plus Code I D and AIM I D You can string together several entries for several symbologies at one time Enter prefixes and suffixes in the order in which you want them to appear on the output When setti...

Page 68: ...thout saving Repeat Steps 1 6 to add a prefix or suffix for another symbology Example Add a Suffix to a specific symbology To send a CR carriage return Suffix for U P C only Step 1 Scan Add Suffix Step 2 Determine the 2 digit hex value from the Symbology Chart included in the Symbology Charts beginning on page A 1 for U P C Step 3 Scan 6 3 from the Programming Chart inside the back cover of this m...

Page 69: ...ue from the Programming Chart inside the back cover of this manual or scan 9 9 for all symbologies Your change is automatically saved To Add a Carriage Return Suffix to All Symbologies Scan the following bar code if you wish to add a carriage return suffix to all symbologies at once This action first clears all current suffixes then pro grams a carriage return suffix for all symbologies Prefix Sel...

Page 70: ...ce Keys starting on page 7 3 When the scanner is in keyboard wedge mode the scan code is con verted to a key code before it is transmitted Default Enable Intercharacter Interfunction and Intermessage Delays Some terminals drop information characters if data comes through too quickly Intercharacter interfunction and intermessage delays slow the transmission of data increasing data integrity Add Suf...

Page 71: ...ercharacter Delay An intercharacter delay of up to 5000 milliseconds in 5ms increments may be placed after the transmission of a particular character of scanned data Scan the Delay Length bar code below then scan the number of 5ms delays and the Save bar code using the Programming Chart inside the back cover of this manual Next scan the Character to Trigger Delay bar code then the 2 digit hex valu...

Page 72: ...side the back cover of this manual Intermessage Delay An intermessage delay of up to 5000 milliseconds in 5ms increments may be placed between each scan transmission Scan the Intermessage Delay bar code below then scan the number of 5ms delays and the Save bar code using the Programming Chart inside the back cover of this man ual To remove this delay scan the Intermessage Delay bar code then set t...

Page 73: ...th 3 Specific Terminal ID Universal Code ID Actual Length 4 Specific Terminal ID Universal Code ID Universal Length 5 Universal Terminal ID Actual Code ID Actual Length 6 Universal Terminal ID Actual Code ID Universal Length 7 Universal Terminal ID Universal Code ID Actual Length 8 Universal Terminal ID Universal Code ID Universal Length The maximum size of a data format configuration is 2000 byte...

Page 74: ...x value for that symbology and scan the 2 digit hex value from the Programming Chart inside the back cover of this manual Note If you are creating a data format for Batch Mode Quantity use 35 for the Code I D Step 5 Length Specify what length up to 9999 characters of data will be acceptable for this symbology Scan the four digit data length from the Programming Chart inside the back cover of this ...

Page 75: ...scan 1 2 or 3 depending on the format you are clearing Scan the Terminal Type and Code I D see Symbology Charts on page A 1 and the bar code data length for the specific data format that you want to delete All other formats remain unaffected Clear all Data Formats This clears all data formats Save to exit and save your data format changes Discard to exit without saving any data format changes Clea...

Page 76: ... stands for the numeric value 00 99 for the number of characters and xx stands for the the insert character s hex value for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 beginning on page A 4 for decimal hex and character codes Send all characters up to a particular character F3 Include in the output message all characters from the input message starting with the character at t...

Page 77: ... beginning on page A 4 for decimal hex and character codes Move Commands Move the cursor forward a number of characters F5 Move the cursor ahead nn characters from current cursor position Syntax F5nn where nn is the numeric value 00 99 for the number of characters the cursor should be moved ahead Move the cursor backward a number of characters F6 Move the cursor back nn characters from current cur...

Page 78: ...ax E7xx where xx stands for the search character s hex value for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 beginning on page A 4 for decimal hex and character codes Miscellaneous Commands Suppress characters FB Suppress all occurrences of up to 15 different characters starting at the current cursor position as the cursor is advanced by other commands When the FC command is ...

Page 79: ...ert a delay EF Inserts a delay of up to 49 995 milliseconds in multiples of 5 starting from the current cursor position Syntax EFnnnn where nnnn stands for the delay in 5ms increments up to 9999 This command can only be used with keyboard emulation Data Formatter When Data Formatter is turned Off the bar code data is output to the host as read including prefixes and suffixes You may wish to requir...

Page 80: ...etween these formats Your primary data format is saved under 0 Your other three formats are saved under 1 2 and 3 To set your device to use one of these formats scan one of the bar codes below Data Formatter On Not Required Keep Prefix Suffix Data Format Required Keep Prefix Suffix Primary Data Format Data Format 1 Data Format 2 Data Format 3 ...

Page 81: ... A MSI Codablock F NEC 2 of 5 Code 11 Postal Codes 2D Code 128 Postal Codes Linear Code 32 Pharmaceutical PARAF PDF417 Code 39 GS1 DataBar Omnidirectional Code 93 QR Code Data Matrix Straight 2 of 5 IATA two bar start stop EAN JAN 13 Straight 2 of 5 Industrial three bar start stop EAN JAN 8 TCIF Linked Code 39 TLC39 GS1 Composite Codes Telepen GS1 DataBar Expanded UPC A GS1 DataBar Limited UPC A E...

Page 82: ... scanner will issue an error tone You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data This helps reduce the chances of a misread EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15Max length 15 For a value o...

Page 83: ...rs are created using different modulos You can program the scanner to read only Codabar bar codes with Modulo 16 check characters Default No Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character When Check Character is set to Validate and Transmit the scanner will only read Codabar bar codes printed with a check character ...

Page 84: ...nner looks for a Codabar symbol having a D start character adjacent to a symbol having a D stop character In this case the two mes sages are concatenated into one with the D characters omitted Select Require to prevent the scanner from decoding a single D Codabar symbol without its companion This selection has no effect on Codabar symbols without Stop Start D characters No Check Character Validate...

Page 85: ...e bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 2 60 Minimum Default 4 Maximum Default 60 Minimum Message Length Maximum Message Length ...

Page 86: ...Start Stop characters Default Don t Transmit Code 39 Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character When Check Character is set to Validate but Don t Transmit the unit only reads Code 39 bar codes printed with a check character but will not transmit the check character with the scanned data On Off Transmit Don t Tra...

Page 87: ...length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 0 48 Minimum Default 0 Maximum Default 48 Code 39 Append This function allows the scanner to append the data from several Code 39 bar codes together before transmitting them to the host computer When the scanner encounters a Code 39 bar code with the append trigger char No Check Character Va...

Page 88: ...not have the append trigger The data is then transmitted in the order in which the bar codes were read FIFO Default Off Code 32 Pharmaceutical PARAF Code 32 Pharmaceutical is a form of the Code 39 symbology used by Ital ian pharmacies This symbology is also known as PARAF Off On On Off ...

Page 89: ...as created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page A NUL U DLE P SP SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 R B 2 2 B B R R b B r R ETX C DC3 S C 3 3 C C S S c C s S EOT D DC4 T D ...

Page 90: ...lt All Interleaved 2 of 5 Settings Interleaved 2 of 5 On Off Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit When Check Digit is set to Validate but Don t Transmit the unit only reads Interleaved 2 of 5 bar codes printed with a check digit but will not transmit the check digit with the scanned data Code 39 Code Page On Off ...

Page 91: ...e scanned data Default No Check Digit Interleaved 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Validate but Don t Transmit No Check Digit Validate and Transmit Minimum Message Length Maximum Message Length ...

Page 92: ...but Don t Transmit the unit only reads NEC 2 of 5 bar codes printed with a check digit but will not transmit the check digit with the scanned data When Check Digit is set to Validate and Transmit the scanner only reads NEC 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit On Off No Check Digit Validate and Transmit Valida...

Page 93: ...the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Minimum Message Length Maximum Message Length ...

Page 94: ...ault 0 Maximum Default 80 Code 93 Append This function allows the scanner to append the data from several Code 93 bar codes together before transmitting them to the host computer When this function is enabled the scanner stores those Code 93 bar codes that start with a space excluding the start and stop symbols and does not immediately transmit the data The scanner stores the data in the order in ...

Page 95: ...display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page A 10 and scan the value and the Save bar code from the Programming Chart o...

Page 96: ...of 5 Industrial On Off Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 On Off Minimum Message Length Maximum Message Length ...

Page 97: ...f 5 IATA On Off Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Off On Minimum Message Length Maximum Message Length ...

Page 98: ...atrix 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 On Off Maximum Message Length Minimum Message Length ...

Page 99: ...1 Default All Settings Code 11 On Off Code 11 Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes Default Two Check Digits On Off One Check Digit Two Check Digits ...

Page 100: ...enation In 1994 the International Society of Blood Transfusion ISBT ratified a standard for communicating critical blood information in a uniform manner The use of ISBT formats requires a paid license The ISBT 128 Application Specification describes 1 the critical data elements for labeling blood prod ucts 2 the current recommendation to use Code 128 due to its high degree of security and its spac...

Page 101: ... Maximum lengths 0 80 Minimum Default 0 Maximum Default 80 Code 128 Append This function allows the scanner to append the data from several Code 128 bar codes together before transmitting them to the host computer When the scanner encounters a Code 128 bar code with the append trigger char acter s it buffers Code 128 bar codes until it reads a Code 128 bar code that does not have the append trigge...

Page 102: ...ng a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page A 10 and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual The data characters should then appear properly Code...

Page 103: ... Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 80 Minimum Default 1 Maximum Default 80 On Off Minimum Message Length Maximum Message Length ...

Page 104: ...t stop pat tern 1 and decodes them as standard full ASCII start stop pattern 1 When Original Telepen Output is selected the scanner reads symbols with start stop pattern 1 and decodes them as compressed numeric with optional full ASCII start stop pattern 2 Default AIM Telepen Output On Off Original Telepen Output AIM Telepen Output ...

Page 105: ...e Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 60 Minimum Default 1 Maximum Default 60 UPC A Default All UPC A Settings UPC A On Off Note When UPC A Off is scanned UPC A bar codes are transmitted as EAN 13 Minimum Message Length Maximum Message Length On Off ...

Page 106: ... system digit of a U P C symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will not transmit it Default On UPC A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC A data Default Off for both 2 Digit and 5 Digit Addenda On Off Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On ...

Page 107: ...codes to enable or disable UPC A and EAN 13 with Extended Coupon Code When left on the default setting Off the scanner treats Cou pon Codes and Extended Coupon Codes as single bar codes If you scan the Allow Concatenation code when the scanner sees the coupon code and the extended coupon code in a single scan it transmits both as sepa rate symbologies Otherwise it transmits the first coupon code i...

Page 108: ...UPC and GS1 DataBar codes you may wish to scan and output only the data from the GS1 DataBar code Scan the GS1 Output On code below to scan and output only the GS1 DataBar code data Default GS1 Output Off Allow Concatenation Off Require Concatenation GS1 Output Off GS1 Output On ...

Page 109: ...th the 0 number system To read these codes use the UPC E0 On selection If you need to read codes that lead with the 1 number system use UPC E1 page 6 32 Default On UPC E0 Expand UPC E Expand expands the UPC E code to the 12 digit UPC A format Default Off UPC E0 On UPC E0 Off On Off ...

Page 110: ...0 Addenda Separator When this feature is On there is a space between the data from the bar code and the data from the addenda When turned Off there is no space Default On UPC E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not Default On Not Required Required Off On Off On ...

Page 111: ...data but the unit can be programmed so it will not transmit it To prevent transmission scan Off Default On UPC E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC E data Default Off for both 2 Digit and 5 Digit Addenda Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On ...

Page 112: ...e 6 29 If you need to read codes that lead with the 1 number system use the UPC E1 On selection Default Off EAN JAN 13 Default All EAN JAN Settings EAN JAN 13 On Off Note If you want to convert UPC A bar codes to EAN 13 format scan the UPC A Off bar code on page 6 25 UPC E1 On UPC E1 Off On Off ...

Page 113: ...enda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 13 data Default Off for both 2 Digit and 5 Digit Addenda EAN JAN 13 Addenda Required When Required is scanned the scanner will only read EAN JAN 13 bar codes that have addenda Default Not Required Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required Required ...

Page 114: ...om the addenda When turned Off there is no space Default On Note If you want to enable or disable EAN13 with Extended Coupon Code refer to UPC A EAN 13 with Extended Coupon Code page 6 27 ISBN Translate When On is scanned EAN 13 Bookland symbols are translated into their equivalent ISBN number format Default Off Off On Off On ...

Page 115: ... Default All EAN JAN 8 Settings EAN JAN 8 On Off EAN JAN 8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On On Off Off On ...

Page 116: ...red is scanned the scanner will only read EAN JAN 8 bar codes that have addenda Default Not Required EAN JAN 8 Addenda Separator When this feature is On there is a space between the data from the bar code and the data from the addenda When turned Off there is no space Default On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required Required Off On ...

Page 117: ...ogram the scanner to read MSI bar codes with Type 10 check charac ters Default Validate Type 10 but Don t Transmit When Check Character is set to Validate Type 10 11 and Transmit the scanner will only read MSI bar codes printed with the specified type check character s and will transmit the character s at the end of the scanned data On Off ...

Page 118: ... length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Validate Type 10 and Transmit Validate Type 10 but Don t Transmit Validate 2 Type 10 Characters but Don t Transmit Validate 2 Type 10 Characters and Transmit Validate Type 11 then Type 10 Character but Don t Transmit Validate Type 11 then Type 10 Ch...

Page 119: ... DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings GS1 DataBar Omnidirectional On Off GS1 DataBar Limited Default All GS1 DataBar Limited Settings GS1 DataBar Limited On Off On Off On Off ...

Page 120: ...n Off GS1 DataBar Expanded Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 4 74 Minimum Default 4 Maximum Default 74 On Off Minimum Message Length Maximum Message Length ...

Page 121: ...block A Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 600 Minimum Default 1 Maximum Default 600 On Off Minimum Message Length Maximum Message Length ...

Page 122: ...lock F Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 2048 Minimum Default 1 Maximum Default 2048 On Off Minimum Message Length Maximum Message Length ...

Page 123: ...sage Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 2750 Minimum Default 1 Maximum Default 2750 On Off Maximum Message Length Minimum Message Length ...

Page 124: ...capable of encoding very large amounts of data into multiple PDF417 bar codes When this selection is enabled these multiple bar codes are assembled into a single data string Default On MicroPDF417 Default All MicroPDF417 Settings MicroPDF417 On Off On Off Off On ...

Page 125: ... for the co existence of symbologies already in use Default Off UPC EAN Version Scan the UPC EAN Version On bar code to decode GS1 Composite sym bols that have a U P C or an EAN linear component This does not affect GS1 Composite symbols with a GS1 128 or GS1 linear component Default UPC EAN Version Off Note If you scan coupons that have both UPC and GS1 DataBar codes you may wish to scan and outp...

Page 126: ...ize one data carrier type If GS1 128 Emulation is scanned all retail codes U P C UPC E EAN8 EAN13 are expanded out to 16 digits If the AIM ID is enabled the value will be the GS1 128 AIM ID C1 see Symbology Charts on page A 1 If GS1 DataBar Emulation is scanned all retail codes U P C UPC E EAN8 EAN13 are expanded out to 16 digits If the AIM ID is enabled the value will be the GS1 DataBar AIM ID em...

Page 127: ...d code component All bar code readers are capable of reading the Code 39 linear component The MicroPDF417 component can only be decoded if TLC39 On is selected The linear component may be decoded as Code 39 even if TLC39 is off Default Off GS1 DataBar Emulation GS1 128 Emulation GS1 Emulation Off GS1 Code Expansion Off EAN8 to EAN13 Conversion Off On ...

Page 128: ...dditional information Mini mum and Maximum lengths 1 7089 Minimum Default 1 Maximum Default 7089 QR Code Append This function allows the scanner to append the data from several QR Code bar codes together before transmitting them to the host computer When the scanner encounters an QR Code bar code with the append trigger character s it buffers the number of QR Code bar codes determined by On Off Ma...

Page 129: ...er characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page A 10 and scan the value and the Save bar code from the Programming Chart on the inside the back...

Page 130: ...i mum and Maximum lengths 1 3116 Minimum Default 1 Maximum Default 3116 Data Matrix Append This function allows the scanner to append the data from several Data Matrix bar codes together before transmitting them to the host computer When the scanner encounters an Data Matrix bar code with the append trigger character s it buffers the number of Data Matrix bar codes deter Off On Maximum Message Len...

Page 131: ...h the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page A 10 and scan the value and the Save bar code from the Programming Chart on the insid...

Page 132: ...e Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 150 Minimum Default 1 Maximum Default 150 On Off Minimum Message Length Maximum Message Length ...

Page 133: ...e 6 2 for additional information Mini mum and Maximum lengths 1 3832 Minimum Default 1 Maximum Default 3832 Aztec Append This function allows the scanner to append the data from several Aztec bar codes together before transmitting them to the host computer When the scanner encounters an Aztec bar code with the append trigger charac Off On Maximum Message Length Minimum Message Length ...

Page 134: ...d does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page A 10 and scan the value and the Save bar code from the Programm...

Page 135: ...th Description page 6 2 for additional information Mini mum and Maximum lengths 1 7833 Minimum Default 1 Maximum Default 7833 Postal Codes Linear The following lists linear postal codes Any combination of linear postal code selections can be active at a time China Post Hong Kong 2 of 5 Default All China Post Hong Kong 2 of 5 Settings Off On Maximum Message Length Minimum Message Length ...

Page 136: ... 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maxi mum Default 80 On Off Minimum Message Length Maximum Message Length ...

Page 137: ...tion page 6 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maxi mum Default 48 Korea Post Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data Default Don t Transmit On Off Minimum Message Length Maximum Message Length Don t Transmit Check Digit Transmit Check Digit ...

Page 138: ... Only one 2D postal code selection can be active at a time If you scan a second 2D postal code selection the first selection is over written Default 2D Postal Codes Off Single 2D Postal Codes 2D Postal Codes Off Australian Post On British Post On Canadian Post On Intelligent Mail Bar Code On Japanese Post On KIX Post On ...

Page 139: ...de On Also see Planet Code Check Digit page 6 62 Postal 4i On Postnet On Also see Postnet Check Digit page 6 62 Postnet with B and B Fields On InfoMail On InfoMail and British Post On Intelligent Mail Bar Code and Postnet with B and B Fields On ...

Page 140: ...t Mail Bar Code On Postal 4i and Intelligent Mail Bar Code On Postal 4i and Postnet with B and B Fields On Planet Code and Postnet On Planet Code and Postnet with B and B Fields On Planet Code and Postal 4i On Planet Code and Intelligent Mail Bar Code On ...

Page 141: ...t Code Postal 4i and Intelligent Mail Bar Code On Postnet Postal 4i and Intelligent Mail Bar Code On Planet Code Postal 4i and Postnet with B and B Fields On Planet Code Intelligent Mail Bar Code and Postnet with B and B Fields On Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On ...

Page 142: ... Digit This selection allows you to specify whether the check digit should be transmitted at the end of Postnet data Default Don t Transmit Planet Code Postal 4i Intelligent Mail Bar Code and Postnet On Planet Code Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On Transmit Check Digit Don t Transmit Check Digit Transmit Check Digit Don t Transmit Check Digit ...

Page 143: ...ic N Table causes that field to be interpreted as numeric data using the N Table Alphanumeric C Table causes the field to be interpreted as alphanumeric data using the C Table Refer to the Australian Post Specification Tables Combination C and N Tables causes the field to be interpreted using either the C or N Tables Bar Output Numeric N Table Alphanumeric C Table Combination C and N Tables ...

Page 144: ...6 64 ...

Page 145: ...used with the scanner Refer to page 2 18 enable Control ASCII mode Function Code HEX ASCII Value Full ASCII CTRL NUL 00 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08 H HT 09 I LF 0A J VT 0B K FF 0C L CR 0D M SO 0E N SI 0F O DLE 10 P DC1 11 Q DC2 12 R DC3 13 S DC4 14 T NAK 15 U SYN 16 V ETB 17 W CAN 18 X EM 19 Y SUB 1A Z ESC 1B FS 1C GS 1D RS 1E US 1F _ ...

Page 146: ...ply to US only The following chart indicates the equivalents of these five characters for different countries Country Codes United States 6 Belgium 6 Scandinavia 8 9 6 France 8 6 Germany à 6 Italy 6 Switzerland 6 United Kingdom 6 Denmark 8 9 6 Norway 8 9 6 Spain 6 ...

Page 147: ... 06 CTRL break CNTRL break BEL 07 CR Enter RETURN BS 08 Reserved APPLE make HT 09 Tab TAB LF 0A Reserved APPLE break VT 0B Tab TAB FF 0C Delete Del CR 0D CR Enter RETURN SO 0E Insert Ins Help SI 0F Escape ESC DLE 10 F11 F11 DC1 11 Home Home DC2 12 Print Prnt Scrn DC3 13 Back Space BACKSPACE DC4 14 Back Tab LSHIFT TAB NAK 15 F12 F12 SYN 16 F1 F1 ETB 17 F2 F2 CAN 18 F3 F3 EM 19 F4 F4 SUB 1A F5 F5 ES...

Page 148: ...7 4 ...

Page 149: ...or all symbologies This is a temporary setting that will be removed when the unit is power cycled Show Decoder Revision Scan the bar code below to output the decoder revision Show Scan Driver Revision Scan the bar code below to output the scan driver revision The scan driver controls image capture Show Software Revision Scan the bar code below to output the current software revision unit serial nu...

Page 150: ...ogrammed parameters and create and print programming bar codes Using EZConfig Scanning you can even save open the programming parame ters for a scanner This saved file can be e mailed or if required you can cre ate a single bar code that contains all the customized programming parameters and mail or fax that bar code to any location Users in other locations can scan the bar code to load in the cus...

Page 151: ...specified for a scanner You can set or modify these parameters as required You can later write the modified settings to the scanner or save them to a dcf file Installing EZConfig Scanning from the Web Note EZConfig Scanning requires NET software If NET is not installed on your PC you will be prompted to install it during the EZConfig Scanning installation 1 Access the Honeywell web site at www hon...

Page 152: ...om Defaults bar code then scan Activate Defaults This resets the scanner to the factory default settings The Menu Commands beginning on page 9 5 list the factory default settings for each of the commands indicated by an asterisk on the programming pages This selection erases all your settings and resets the scanner to the original factory defaults It also disables all plugins Remove Custom Default...

Page 153: ... Data SubTag Data Tag SubTag Data Storage Prefix Three ASCII characters SYN M CR ASCII 22 77 13 Name To send information to the scanner use Voyager The default factory setting for a Voyager scanner is Voyager scanner This setting is changed by using the BT_NAM command which accepts alphanumeric values If the name is not known a wildcard can be used Tag A 3 character case insensitive field that ide...

Page 154: ...ce of a SubTag field the query applies only to the subset of commands available that match the Tag field In this case the Data field should not be used because it is ignored by the device Data Field Usage When a query is used in place of the Data field the query applies only to the specific command identified by the Tag and SubTag fields Concatenation of Multiple Commands Multiple commands can be ...

Page 155: ...indicates that Codabar Coding Enable CBRENA has a range of values from 0 to 1 off and on Example What is the default value for Codabar Coding Enable Enter cbrena Response CBRENA1 ACK This response indicates that the default setting for Codabar Coding Enable CBRENA is 1 or on Example What is the device s current setting for Codabar Coding Enable Enter cbrena Response CBRENA1 ACK This response indic...

Page 156: ...te Custom Defaults bar code below This resets the scanner to the custom default settings If there are no custom defaults it will reset the scanner to the factory default settings Any settings that have not been specified through the custom defaults will be defaulted to the factory default settings The charts on the following pages list the factory default settings for each of the commands indicate...

Page 157: ...yboard Wedge IBM PC AT and Compatibles with CR suffix PAP_AT 2 1 Laptop Direct Connect with CR suffix PAPLTD 2 1 RS232 Serial Port PAP232 2 2 Plug and Play Codes RS485 IBM Port 5B Interface PAPP5B 2 2 IBM Port 9B HHBCR 1 Interface PAP9B1 2 2 IBM Port 17 Interface PAPP17 2 2 IBM Port 9B HHBCR 2 Interface PAP9B2 2 2 RS485 Packet Mode On RTLPDF1 2 3 RS485 Packet Mode Off RTLPDF0 2 3 RS485 Packet Leng...

Page 158: ...f USBCTS0 2 5 ACK NAK Mode On USBACK1 2 5 ACK NAK Mode Off USBACK0 2 5 Plug and Play Codes Verifone Ruby Terminal PAPRBY 2 6 Gilbarco Terminal PAPGLB 2 6 Honeywell Bioptic Aux Port PAPBIO 2 7 Datalogic Magellan Bioptic Aux Port PAPMAG 2 7 NCR Bioptic Aux Port PAPNCR 2 7 Wincor Nixdorf Terminal PAPWNX 2 8 Wincor Nixdorf Beetle PAPBTL 2 8 Selection Setting Indicates default Serial Command Indicates ...

Page 159: ...CTY1 2 9 Bosnia KBDCTY33 2 9 Brazil KBDCTY16 2 9 Brazil MS KBDCTY59 2 10 Bulgaria Cyrillic KBDCTY52 2 10 Bulgaria Latin KBDCTY53 2 10 Canada French legacy KBDCTY54 2 10 Canada French KBDCTY18 2 10 Canada Multilingual KBDCTY55 2 10 Croatia KBDCTY32 2 10 Czech KBDCTY15 2 10 Selection Setting Indicates default Serial Command Indicates a numeric entry Page ...

Page 160: ...CTY64 2 11 Greek 220 KBDCTY61 2 11 Greek 319 Latin KBDCTY65 2 11 Greek 319 KBDCTY62 2 11 Greek Latin KBDCTY63 2 11 Greek MS KBDCTY66 2 11 Greek Polytonic KBDCTY60 2 12 Hebrew KBDCTY12 2 12 Hungarian 101 key KBDCTY50 2 12 Hungary KBDCTY19 2 12 Iceland KBDCTY75 2 12 Irish KBDCTY73 2 12 Italian 142 KBDCTY56 2 12 Italy KBDCTY5 2 12 Japan ASCII KBDCTY28 2 12 Kazakh KBDCTY78 2 12 Kyrgyz Cyrillic KBDCTY7...

Page 161: ...KBDCTY26 2 13 Russian MS KBDCTY67 2 14 Russian Typewriter KBDCTY68 2 14 SCS KBDCTY21 2 14 Serbia Cyrillic KBDCTY37 2 14 Serbia Latin KBDCTY36 2 14 Slovakia KBDCTY22 2 14 Slovakia QWERTY KBDCTY49 2 14 Slovakia QWERTZ KBDCTY48 2 14 Slovenia KBDCTY31 2 14 Spain KBDCTY10 2 14 Spanish variation KBDCTY51 2 14 Sweden KBDCTY23 2 14 Switzerland French KBDCTY29 2 14 Switzerland German KBDCTY6 2 15 Tatar KBD...

Page 162: ...sion Keyboard Conversion Off KBDCNV0 2 17 Convert all Characters to Upper Case KBDCNV1 2 17 Convert all Characters to Lower Case KBDCNV1 2 17 Keyboard Style Regular KBDSTY0 2 16 Caps Lock KBDSTY1 2 16 Shift Lock KBDSTY2 2 16 Automatic Caps Lock KBDSTY6 2 16 Emulate External Keyboard KBDSTY5 2 17 Control Character Output Control Character Output Off KBDNPE0 2 18 Control Character Output On KBDNPE1 ...

Page 163: ...eypad Off KBDNPS0 2 19 Numeric Keypad On KBDNPS1 2 19 Auto Direct Connect Off KBDADC0 2 19 Auto Direct Connect On KBDADC1 2 19 Baud Rate 300 BPS 232BAD0 2 20 600 BPS 232BAD1 2 20 1200 BPS 232BAD2 2 20 2400 BPS 232BAD3 2 20 4800 BPS 232BAD4 2 20 9600 BPS 232BAD5 2 20 19200 BPS 232BAD6 2 20 38400 BPS 232BAD7 2 20 57600 BPS 232BAD8 2 20 115200 BPS 232BAD9 2 20 Selection Setting Indicates default Seri...

Page 164: ...2 2 21 8 Data 1 Stop Parity Odd 232WRD8 2 21 RS232 Receiver Time out Range 0 300 seconds 232LPT 2 22 RS232 Handshaking RTS CTS Off 232CTS0 2 22 Flow Control No Timeout 232CTS1 2 22 Two Direction Flow Control 232CTS2 2 22 Flow Control with Timeout 232CTS3 2 22 RS232 Timeout 232DEL 2 23 XON XOFF Off 232XON0 2 23 XON XOFF On 232XON1 2 23 ACK NAK Off 232ACK0 2 24 ACK NAK On 232ACK1 2 24 Scanner Biopti...

Page 165: ... BEPTRG1 3 1 Off BEPTRG0 3 1 Beeper Good Read Off BEPBEP0 3 2 On BEPBEP1 3 2 Beeper Volume Good Read Off BEPLVL0 3 2 Low BEPLVL1 3 2 Medium BEPLVL2 3 2 High BEPLVL3 3 2 Beeper Pitch Good Read Frequency Low 1600 min 400Hz BEPFQ11600 3 3 Medium 2400 BEPFQ12400 3 3 High 4200 max 9000Hz BEPFQ14200 3 3 Beeper Pitch Error Frequency Razz 250 min 200Hz BEPFQ2800 3 3 Medium 3250 BEPFQ23250 3 3 High 4200 ma...

Page 166: ...ad Delay Range 0 30 000 ms DLYGRD 3 5 Manual Trigger Mode Manual Trigger Normal PAPHHF 3 5 LED Illumination Manual Trigger Low PWRNOL7 3 6 Medium PWRNOL15 3 6 Medium High PWRNOL50 3 6 High PWRNOL150 3 6 In Stand Sensor Mode Sensor On TRGSSW1 3 6 Sensor Off TRGSSW0 3 6 Presentation Presentation Mode PAPPST 3 7 Idle Illumination Presentation Mode Low PWRIDL7 3 7 Medium PWRIDL15 3 7 High PWRIDL50 3 7...

Page 167: ... CodeGate CodeGate Off Out of Stand AOSCGD0 3 9 CodeGate On Out of Stand AOSCGD1 3 9 Mobile Phone Read Mode Hand Held Scanning Mobile Phone PAPHHC 3 10 Presentation Scanning Mobile Phone PAPPSC 3 10 Hands Free Time Out Range 0 300 000 ms TRGPTO 3 10 Reread Delay Short 500 ms DLYRRD500 3 11 Medium 750 ms DLYRRD750 3 11 Long 1000 ms DLYRRD1000 3 11 Extra Long 2000 ms DLYRRD2000 3 10 User Specified R...

Page 168: ...dard Bar Codes VIDREV2 3 14 Video Reverse Off VIDREV0 3 14 Working Orientation Upright ROTATN0 3 15 Vertical Bottom to Top Rotate CCW 90 ROTATN1 3 15 Upside Down ROTATN2 3 15 Vertical Top to Bottom Rotate CW 90 ROTATN3 3 15 Prefix Suffix Selections Add CR Suffix to All Symbologies VSUFCR 4 3 Prefix Add Prefix PREBK2 4 3 Clear One Prefix PRECL2 4 3 Clear All Prefixes PRECA2 4 3 Suffix Add Suffix SU...

Page 169: ... 6 Data Formatter Selections Data Format Editor Default Data Format None DFMDF3 5 1 Enter Data Format DFMBK3 5 2 Clear One Data Format DFMCL3 5 3 Clear All Data Formats DFMCA3 5 3 Data Formatter Data Formatter Off DFM_EN0 5 7 Data Formatter On Not Required Keep Prefix Suffix DFM_EN1 5 8 Data Format Required Keep Prefix Suffix DFM_EN2 5 8 Primary Alternate Data Formats Primary Data Format ALTFNM0 5...

Page 170: ...Validate and Transmit CBRCK22 6 4 Codabar Concatenation Off CBRCCT0 6 4 On CBRCCT1 6 4 Require CBRCCT2 6 4 Codabar Message Length Minimum 2 60 4 CBRMIN 6 5 Maximum 2 60 60 CBRMAX 6 5 Code 39 Default All Code 39 Settings C39DFT 6 6 Off C39ENA0 6 6 On C39ENA1 6 6 Code 39 Start Stop Char Don t Transmit C39SSX0 6 6 Transmit C39SSX1 6 6 Code 39 Check Char No Check Char C39CK20 6 7 Validate But Don t Tr...

Page 171: ...5ENA0 6 10 On I25ENA1 6 10 Interleaved 2 of 5 Check Digit No Check Char I25CK20 6 11 Validate But Don t Transmit I25CK21 6 11 Validate and Transmit I25CK22 6 11 Interleaved 2 of 5 Message Length Minimum 2 80 4 I25MIN 6 11 Maximum 2 80 80 I25MAX 6 11 NEC 2 of 5 Default All NEC 2 of 5 Settings N25DFT 6 12 Off N25ENA0 6 12 On N25ENA1 6 12 NEC 2 of 5 Check Digit No Check Char N25CK20 6 12 Validate But...

Page 172: ... All Straight 2 of 5 Industrial Settings R25DFT 6 16 Off R25ENA0 6 16 On R25ENA1 6 16 Straight 2 of 5 Industrial Message Length Minimum 1 48 4 R25MIN 6 16 Maximum 1 48 48 R25MAX 6 16 Straight 2 of 5 IATA Default All Straight 2 of 5 IATA Settings A25DFT 6 17 Straight 2 of 5 IATA Off A25ENA0 6 17 On A25ENA1 6 17 Straight 2 of 5 IATA Message Length Minimum 1 48 4 A25MIN 6 17 Maximum 1 48 48 A25MAX 6 ...

Page 173: ...fault All Code 128 Settings 128DFT 6 20 Off 128ENA0 6 20 On 128ENA1 6 20 ISBT Concatenation Off ISBENA0 6 21 On ISBENA1 6 21 Code 128 Message Length Minimum 0 80 0 128MIN 6 21 Maximum 0 80 80 128MAX 6 21 Code 128 Append On 128APP1 6 21 Off 128APP0 6 21 Code 128 Code Page Code 128 Code Page 2 128DCP 6 22 GS1 128 Default All GS1 128 Settings GS1DFT 6 23 On GS1ENA1 6 23 Off GS1ENA0 6 23 GS1 128 Messa...

Page 174: ... UPC A Number System Off UPANSX0 6 26 On UPANSX1 6 26 UPC A 2 Digit Addenda Off UPAAD20 6 26 On UPAAD21 6 26 UPC A 5 Digit Addenda Off UPAAD50 6 26 On UPAAD51 6 26 UPC A Addenda Required Not Required UPAARQ0 6 27 Required UPAARQ1 6 27 UPC A Addenda Separator Off UPAADS0 6 27 On UPAADS1 6 27 UPC A EAN 13 with Extended Coupon Code Off CPNENA0 6 28 Allow Concatenation CPNENA1 6 28 Require Concatenati...

Page 175: ...EAD21 6 31 2 Digit Addenda Off UPEAD20 6 31 5 Digit Addenda On UPEAD51 6 31 5 Digit Addenda Off UPEAD50 6 31 UPC E1 Off UPEEN10 6 32 On UPEEN11 6 32 EAN JAN 13 Default All EAN JAN Settings E13DFT 6 32 Off E13ENA0 6 32 On E13ENA1 6 32 EAN JAN 13 Check Digit Off E13CKX0 6 33 On E13CKX1 6 32 EAN JAN 13 2 Digit Addenda 2 Digit Addenda On E13AD21 6 33 2 Digit Addenda Off E13AD20 6 33 5 Digit Addenda On...

Page 176: ...KX1 6 35 EAN JAN 8 Addenda 2 Digit Addenda Off EA8AD20 6 36 2 Digit Addenda On EA8AD21 6 36 5 Digit Addenda Off EA8AD50 6 36 5 Digit Addenda On EA8AD51 6 36 EAN JAN 8 Addenda Required Not Required EA8ARQ0 6 36 Required EA8ARQ1 6 36 EAN JAN 8 Addenda Separator Off EA8ADS0 6 36 On EA8ADS1 6 36 MSI Default All MSI Settings MSIDFT 6 37 Off MSIENA0 6 37 On MSIENA1 6 37 Selection Setting Indicates defau...

Page 177: ... 38 Validate Type 10 then Type 11 Char and Transmit MSICHK5 6 38 Disable MSI Check Characters MSICHK6 6 38 MSI Message Length Minimum 4 48 4 MSIMIN 6 38 Maximum 4 48 48 MSIMAX 6 38 GS1 DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings RSSDFT 6 39 Off RSSENA0 6 39 On RSSENA1 6 39 GS1 DataBar Limited Default All GS1 DataBar Limited Settings RSLDFT 6 39 Off RSLENA0 6 39 On RSLE...

Page 178: ...dablock A Msg Length Minimum 1 600 1 CBAMIN 6 41 Maximum 1 600 600 CBAMAX 6 41 Codablock F Default All Codablock F Settings CBFDFT 6 42 Off CBFENA0 6 42 On CBFENA1 6 42 Codablock F Msg Length Minimum 1 2048 1 CBFMIN 6 42 Maximum 1 2048 2048 CBFMAX 6 42 PDF417 Default All PDF417 Settings PDFDFT 6 43 On PDFENA1 6 43 Off PDFENA0 6 43 PDF417 Msg Length Minimum 1 2750 1 PDFMIN 6 43 Maximum 1 2750 2750 ...

Page 179: ...ff COMUPC0 6 45 GS1 Composite Codes Msg Length Minimum 1 2435 1 COMMIN 6 46 Maximum 1 2435 2435 COMMAX 6 46 GS1 Emulation GS1 128 Emulation EANEMU1 6 47 GS1 DataBar Emulation EANEMU2 6 47 GS1 Code Expansion Off EANEMU3 6 47 EAN8 to EAN13 Conversion EANEMU4 6 47 GS1 Emulation Off EANEMU0 6 47 TCIF Linked Code 39 On T39ENA1 6 47 Off T39ENA0 6 47 QR Code Default All QR Code Settings QRCDFT 6 55 On QR...

Page 180: ...IDMMAX 6 50 Data Matrix Append On IDMAPP1 6 51 Off IDMAPP0 6 51 Data Matrix Code Page Data Matrix Code Page 51 IDMDCP 6 51 MaxiCode Default All MaxiCode Settings MAXDFT 6 52 On MAXENA1 6 52 Off MAXENA0 6 52 MaxiCode Msg Length Minimum 1 150 1 MAXMIN 6 52 Maximum 1 150 150 MAXMAX 6 52 Aztec Code Default All Aztec Code Settings AZTDFT 6 53 On AZTENA1 6 53 Off AZTENA0 6 53 Aztec Code Msg Length Minim...

Page 181: ... China Post Hong Kong 2 of 5 Settings CPCDFT 6 55 Off CPCENA0 6 56 On CPCENA1 6 56 China Post Hong Kong 2 of 5 Msg Length Minimum 2 80 4 CPCMIN 6 56 Maximum 2 80 80 CPCMAX 6 56 Korea Post Default All Korea Post Settings KPCDFT 6 57 Off KPCENA0 6 57 On KPCENA1 6 57 Korea Post Msg Length Minimum 2 80 4 KPCMIN 6 57 Maximum 2 80 48 KPCMAX 6 57 Korea Post Check Digit Transmit Check Digit KPCCHK1 6 57 D...

Page 182: ...elligent Mail Bar Code On POSTAL10 6 58 Japanese Post On POSTAL3 6 58 KIX Post On POSTAL4 6 58 Planet Code On POSTAL5 6 59 Postal 4i On POSTAL9 6 59 Postnet On POSTAL6 6 59 Postnet with B and B Fields On POSTAL11 6 59 InfoMail On POSTAL2 6 59 Selection Setting Indicates default Serial Command Indicates a numeric entry Page ...

Page 183: ...60 Postal 4i and Postnet with B and B Fields On POSTAL19 6 60 Planet and Postnet On POSTAL12 6 60 Planet and Postnet with B and B Fields On POSTAL18 6 60 Planet and Postal 4i On POSTAL13 6 60 Planet and Intelligent Mail Bar Code On POSTAL15 6 60 Planet Postnet and Postal 4i On POSTAL21 6 61 Planet Postnet and Intelligent Mail Bar Code On POSTAL22 6 61 Planet Postal 4i and Intelligent Mail Bar Code...

Page 184: ...and Postnet On POSTAL28 6 62 Planet Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On POSTAL29 6 62 Planet Code Check Digit Transmit PLNCKX1 6 62 Don t Transmit PLNCKX0 6 62 Postnet Check Digit Transmit NETCKX1 6 62 Don t Transmit NETCKX0 6 62 Australian Post Interpretation Bar Output AUSINT0 6 63 Numeric N Table AUSINT1 6 63 Alphanumeric C Table AUSINT2 6 63 Combination N and...

Page 185: ...Revision REV_SD 8 1 Show Software Revision REVINF 8 1 Show Data Format DFMBK3 8 2 Resetting the Factory Defaults Remove Custom Defaults DEFOVR 8 4 Activate Defaults DEFALT 8 4 Selection Setting Indicates default Serial Command Indicates a numeric entry Page ...

Page 186: ...9 34 ...

Page 187: ...4 F 0 C to 40 C Storage Temperature 40 F to 140 F 40 C to 60 C Humidity 5 to 95 non condensing Drop Operational after 30 drops to concrete from 5 ft 1 5m Environmental Sealing IP42 Light Levels 0 100 000 lux direct sunlight ESD 4kv direct discharge 8kv air discharge Image Image Size 640x480 Scan Performance Pitch Skew 60 70 Motion Tolerance Presentation Mode up to 10cm per second for 13 mil UPC Sy...

Page 188: ...il PDF417 35 100mm 1 4 3 9 in 10mil Data Matrix 35 105mm 1 4 4 1 in 20mil QR Code 25 205mm 1 1 81 in Guaranteed Performance 5 mil Code 39 50 95mm 2 3 7 in 13 mil UPC A 34 200mm 1 3 7 9 in Parameter Specification ...

Page 189: ...t provided by the manufacturer may result in damage not covered by your warranty Keyboard Wedge 10 Pin RJ41 Modular Plug Serial Output 10 Pin RJ41 Modular Plug 1 Cable shield 2 Cable select 3 Supply ground 4 Terminal data 5 Terminal clock 6 Keyboard clock 7 5V power 8 Keyboard data 9 10 1 Cable shield 2 Cable select 3 Supply ground 4 Transmit data 5 Receive data serial data to scanner 6 CTS 7 5V p...

Page 190: ...ote RS485 signal conversion is performed in the cable 1 Cable shield 2 Cable select 3 Supply ground 4 5 6 7 5V power 8 9 Data 10 Data 1 Cable shield 2 Cable select 3 Supply ground 4 Transmit data 5 Receive data serial data to scanner 6 7 5V power 8 Transmit Enable 9 10 ...

Page 191: ...th water only The scanner and base s housing may also be cleaned the same way Inspecting Cords and Connectors Inspect the interface cable and connector for wear or other signs of dam age A badly worn cable or damaged connector may interfere with scanner operation Contact your distributor for information about cable replace ment Cable replacement instructions are on page 11 1 Replacing Cables The s...

Page 192: ...ay and will click into place Troubleshooting a Voyager 1400g Scanner The scanner automatically performs self tests whenever you turn it on If your scanner is not functioning properly review the following Troubleshoot ing Guide to try to isolate the problem Is the power on Is the aimer on If the aimer isn t illuminated check that The cable is connected properly The host system power is on if extern...

Page 193: ... Play bar code See Programming the Interface beginning on page 2 1 The scanner may not be programmed to output your bar code data properly For example you scan 12345 and the host displays A12345B Reprogram the scanner with the proper symbology selections See Chapter 6 The scanner won t read your bar code at all Scan the sample bar codes in the back of this manual If the scanner reads the sample ba...

Page 194: ...11 4 ...

Page 195: ...Product Service and Repair Honeywell International Inc provides service for all of its products through service centers throughout the world To obtain warranty or non warranty service please visit www honeywellaidc com and select Support Contact Service and Repair to see your region s instructions on how to obtain a Return Material Authorization number RMA You should do this prior to returning the...

Page 196: ...OR REPLACEMENT OF THE DEFECTIVE PRODUCT WITH NEW OR REFURBISHED PARTS IN NO EVENT SHALL HII BE LIABLE FOR INDIRECT INCIDENTAL OR CONSE QUENTIAL DAMAGES AND IN NO EVENT SHALL ANY LIABILITY OF HII ARISING IN CONNECTION WITH ANY PRODUCT SOLD HEREUNDER WHETHER SUCH LIABILITY ARISES FROM A CLAIM BASED ON CON TRACT WARRANTY TORT OR OTHERWISE EXCEED THE ACTUAL AMOUNT PAID TO HII FOR THE PRODUCT THESE LIM...

Page 197: ...g beginning on page 5 1 for information about using Code ID and AIM ID Linear Symbologies AIM Honeywell Symbology ID Possible modifiers m ID Hex All Symbologies 99 Codabar Fm 0 1 a 61 Code 11 H3 h 68 Code 128 Cm 0 1 2 4 j 6A Code 32 Pharmaceutical PARAF X0 3C Code 39 supports Full ASCII mode Am 0 1 3 4 5 7 b 62 TCIF Linked Code 39 TLC39 L2 T 54 Code 93 and 93i Gm 0 9 A Z a m i 69 EAN Em 0 1 3 4 d ...

Page 198: ... Y 59 Straight 2 of 5 IATA Rm 0 1 3 f 66 Straight 2 of 5 Industrial S0 f 66 MSI Mm 0 1 g 67 Telepen Bm t 74 UPC 0 1 2 3 8 9 A B C UPC A E0 c 63 UPC A with Add On E3 c 63 UPC A with Extended Coupon Code E3 c 63 UPC E E0 E 45 UPC E with Add On E3 E 45 UPC E1 X0 E 45 Add Honeywell Code ID 5C80 Add AIM Code ID 5C81 Add Backslash 5C5C Batch mode quantity 5 35 AIM Honeywell Symbology ID Possible modifie...

Page 199: ... 56 Codablock F Om 0 1 4 5 6 q 71 Code 49 Tm 0 1 2 4 l 6C Data Matrix dm 0 6 w 77 GS1 em 0 3 y 79 GS1 Composite em 0 3 y 79 GS1 DataBar Omnidirectional em 0 3 y 79 MaxiCode Um 0 3 x 78 PDF417 Lm 0 2 r 72 MicroPDF417 Lm 0 5 R 52 QR Code Qm 0 6 s 73 Micro QR Code Qm s 73 AIM Honeywell Symbology ID Possible modifiers m ID Hex All Symbologies 99 Australian Post X0 A 41 British Post X0 B 42 Canadian Po...

Page 200: ... J 4A KIX Netherlands Post X0 K 4B Korea Post X0 3F Planet Code X0 L 4C Postal 4i X0 N 4E Postnet X0 P 50 Non printable ASCII control characters Keyboard Control ASCII CTRL X Mode Control X Mode Off KBDCAS0 Windows Mode Control X Mode On KBDCAS2 DEC HEX Char CTRL X CTRL X function 0 00 NUL Reserved CTRL 1 01 SOH NP Enter CTRL A Select all 2 02 STX Caps Lock CTRL B Bold 3 03 ETX ALT Make CTRL C Cop...

Page 201: ... CTRL T 21 15 NAK F12 CTRL U 22 16 SYN F1 CTRL V Paste 23 17 ETB F2 CTRL W 24 18 CAN F3 CTRL X 25 19 EM F4 CTRL Y 26 1A SUB F5 CTRL Z 27 1B ESC F6 CTRL 28 1C FS F7 CTRL 29 1D GS F8 CTRL 30 1E RS F9 CTRL 31 1F US F10 CTRL 127 7F NP Enter Printable Characters DEC HEX Character DEC HEX Character DEC HEX Character 32 20 SPACE 64 40 96 60 33 21 65 41 A 97 61 a 34 22 66 42 B 98 62 b 35 23 67 43 C 99 63 ...

Page 202: ...s 52 34 4 84 54 T 116 74 t 53 35 5 85 55 U 117 75 u 54 36 6 86 56 V 118 76 v 55 37 7 87 57 W 119 77 w 56 38 8 88 58 X 120 78 x 57 39 9 89 59 Y 121 79 y 58 3A 90 5A Z 122 7A z 59 3B 91 5B 123 7B 60 3C 92 5C 124 7C 61 3D 93 5D 125 7D 62 3E 94 5E 126 7E 63 3F 95 5F _ 127 7F Extended ASCII Characters DEC HEX CP 1252 ASCII Alternate Extended PS2 Scan Code 128 80 Ç up arrow 0x48 129 81 ü down arrow 0x50...

Page 203: ...7 ù F8 0x42 152 98 ÿ F9 0x43 153 99 Ö F10 0x44 154 9A š Ü F11 0x57 155 9B F12 0x58 156 9C œ Numeric Keypad 0x4E 157 9D Numeric Keypad 0x4A 158 9E ž Numeric Keypad 0x37 159 9F Ÿ ƒ Caps Lock 0x3A 160 A0 á Num Lock 0x45 161 A1 í Left Alt 0x38 162 A2 ó Left Ctrl 0x1D 163 A3 ú Left Shift 0x2A 164 A4 ñ Right Shift 0x36 165 A5 Ñ Print Screen n a 166 A6 ª Tab 0x0F 167 A7 º Shift Tab 0x8F 168 A8 Enter 0x1C...

Page 204: ...81 B5 µ 182 B6 183 B7 184 B8 185 B9 186 BA º 187 BB 188 BC 189 BD 190 BE 191 BF 192 C0 À 193 C1 Á 194 C2 Â 195 C3 Ã 196 C4 Ä 197 C5 Å í 198 C6 Æ 199 C7 Ç 200 C8 È 201 C9 É 202 CA Ê 203 CB Ë 204 CC Ì 205 CD Í 206 CE Î 207 CF Ï 208 D0 Ð 209 D1 Ñ 210 D2 Ò 211 D3 Ó Extended ASCII Characters Continued DEC HEX CP 1252 ASCII Alternate Extended PS2 Scan Code ...

Page 205: ...6 E2 â Γ 227 E3 ã π 228 E4 ä Σ 229 E5 å σ 230 E6 æ µ 231 E7 ç τ 232 E8 è Φ 233 E9 é Θ 234 EA ê Ω 235 EB ë δ 236 EC ì 237 ED í φ 238 EE î ε 239 EF ï 240 F0 ð 241 F1 ñ 242 F2 ò 243 F3 ó 244 F4 ô 245 F5 õ 246 F6 ö 247 F7 248 F8 ø 249 F9 ù 250 FA ú Extended ASCII Characters Continued DEC HEX CP 1252 ASCII Alternate Extended PS2 Scan Code ...

Page 206: ... FD ý 254 FE þ 255 FF ÿ Code Page Selection Method Country Standard Keyboard Country Honeywell Code Page Option United States standard ASCII ISO IEC 646 IRV n a 1 Automatic National Character Replacement ISO IEC 2022 n a 2 default Binary Code page n a n a 3 Default Automatic National Character replacement will select the below Honeywell Code Page options for Code128 Code 39 and Code 93 United Stat...

Page 207: ...ed Annex C ISO IEC 646 11 2 82 Ireland ISO IEC 646 207 73 97 Danmark ISO IEC 646 08 8 88 Norway ISO IEC 646 60 9 94 Italy ISO IEC 646 15 5 85 Portugal ISO IEC 646 16 13 92 Spain ISO IEC 646 17 10 90 Spain ISO IEC 646 85 51 91 Code Page Selection Method Country Standard Keyboard Country Honeywell Code Page Option ...

Page 208: ... 28 98 CN 92 99 GB 7 87 FR 3 83 à ç µ é ù è DE 4 84 Ä Ö Ü ä ö ü ß CH 6 86 ù à é ç ê î ô ä ö ü û SE FI 2 82 É Ä Ö Å Ü é ä ö å ü DK 8 88 Æ Ø Å æ ø å NO 9 94 Æ Ø Å æ ø å IE 73 97 Ó É Í Ú Á ó é í ú á IT 5 85 ç é ù à ò è ì PT 13 92 Ã Ç Õ ã ç õ ES 10 90 Ñ ñ ç ES 51 91 Ñ Ç ñ ç COUNTRY Country Keyboard Honeywell CodePage ISO IEC 646 National Character Replacements ...

Page 209: ...54 59 3A 3B 3C 3E 3F 38 40 3D 5A 5F 64 5B 60 65 5C 61 66 5D 62 67 63 68 69 6A 6C 104 Key U S Style Keyboard 6E 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 4B 50 55 4C 51 56 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1E 2C 1F 20 21 22 23 24 25 26 27 28 29 2B 39 2E 2F 30 31 32 33 34 35 36 37 53 4F 54 59 3A 3B 3C 3E 3F 38 40 3D 5A 5F 64 5B 60 65 5C 61 66 5D 62 6...

Page 210: ...A 14 ...

Page 211: ...Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 Code 39 Codabar 1234567890 Code 128 9 780330 290951 BC321 A13579B Code 93 123456 9 Straight 2 of 5 Industrial 123456 ...

Page 212: ...10 GS1 DataBar 01 00123456789012 PDF417 Car Registration Data Matrix QR Code Test Symbol Numbers Matrix 2 of 5 ID tag UPU 4 State J18CUSA8E6N062315014880T 4 CB 4 State Customer Bar Code 01 234 567094 987654321 01234567891 ...

Page 213: ...Sample Symbols Aztec MaxiCode Micro PDF417 Package Label Test Message Test Message Postnet Zip Code ...

Page 214: ...Programming Chart 1 0 2 3 6 7 5 4 8 9 ...

Page 215: ...Programming Chart Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save again A C B F E D Save Discard Reset ...

Page 216: ...VG1400 UG Rev C 9 14 Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 ...

Reviews: