INSTALLATION
Wiring 24 Vac Common
• Single-Transformer System—Connect the common side
of the transformer to the C screw terminal of the
thermostat. Leave the metal jumper wires in place
between R and RC.
• Two-Transformer System—Connect the common side of
the cooling transformer to the C screw terminal of the
thermostat. Remove the metal jumper wire between R
and RC. Connect the hot side of heating transformer to
R and connect the hot side of cooling transformer to RC.
Selecting Discharge Air
Temperature Sensor Mounting
Locations
Refer to the guidelines below and Fig. 3–7 for mounting
locations of the Discharge Air Temperature Sensor.
Selecting Discharge Air Temperature
Sensor Mounting Location
1.
Mount the Discharge Air Temperature Sensor on the
supply duct in a location where the air is mixed well.
Mount the Discharge Air Temperature Sensor out of
sight of the A-Coil/Heat Exchanger when possible.
See Fig. 3.
2.
When possible, mount the Discharge Air Temperature
Sensor upstream of a Steam Humidifier, a Fan
Powered Humidifier or a Dehumidifier that is ducted
to the supply. See Fig. 4–5.
3.
If space does not allow a Discharge Air Temperature
Sensor upstream of a Steam Humidifier or Fan
Powered Humidifier, mount the Discharge Air
Temperature Sensor downstream of the Humidifier.
See Fig. 4.
4.
If a Bypass Humidifier is installed, mount the
Discharge Air Temperature Sensor downstream of the
Bypass Humidifier. See Fig. 6–7.
Selecting Discharge Air Temperature
Sensor Mounting Location
1.
Install the Discharge Air Temperature Sensor on the
duct in a location where the air is mixed well. See
Fig. 3–7.
Fig. 3.
Fig. 4.
Model Numbering
TH8321
Stages
3H/2C HP
2H/2C CONV
Residential or Commercial
Powered - C Wire (C-wire adapter
compatible)
Onboard Humidity Sensor
Number of IAQ Relays
1
Number of Sensor Inputs
1
Economizer / TOD Output
MOUNT DISCHARGE
SENSOR HERE
M35768
HEAT
EXCHANGER
BLOWER
VENTILATOR
OR
DEHUMIDIFIER
A-COIL
M35769
HEAT
EXCHANGER
BLOWER
HUMIDIFIER
ALTERNATE MOUNTING LOCATION
FOR DISCHARGE SENSOR.
MOUNT
DISCHARGE
SENSOR HERE
ABOVE
CENTER
OF A-COIL
UPSTREAM OF
HUMIDIFIER
VENTILATOR
OR
DEHUMIDIFIER