VISIONPRO® 8000 SMART THERMOSTAT
33-00096—04
28
700
Filter Type
None
Elec. Air Cleaner
Media
Media
Both
702
Number of Air
Filters
1 to 2
1
Both
711
Air Filter 1
Reminder
Note: “1” is not
displayed if there is
only 1 filter.
Off
Run Time:
10, 20, 30, 45, 60, 90, 120, 150
days
Calendar:
30, 45, 60, 75 days
3, 4, 5, 6, 9, 12, 15 months
Off
Both
711
Air Filter 2
Reminder
Off
Run Time:
10, 20, 30, 45, 60, 90, 120, 150
days
Calendar:
30, 45, 60, 75 days
3, 4, 5, 6, 9, 12, 15 months
Off
Both
712
EAC Cell Reminder
Off
Calendar Months:
6, 7, 8, 9, 10, 11, 12 months
Off
Both
Electronic Air Cleaner Cell Cleaning Reminder
712
EAC Pre-Filter
Reminder
Off
Calendar Months:
3, 4, 5, 6 months
Off
Both
Electronic Air Cleaner Pre-Filter Cleaning Reminder
712
EAC Post Filter
Reminder
Off
Calendar Months:
6, 7, 8, 9, 10, 11, 12 months
Off
Both
Electronic Air Cleaner Post-Filter Replacement
Reminder
800
Humidifier Type
None
Steam
Bypass / Fan Pwrd
None
Both
803
Humidifier Wiring
U1
Thermostat defaults to
the unused U1
terminals.
Both
U1 are dry contacts that require power. See “Wiring
IAQ Equipment or a Heat/Cool Stage to the U1
Terminals” beginning on page 86.
805
Window Protection
Off
On
Off
Both
Requires a wired outdoor sensor or connection to the
Internet.
Off: The thermostat controls the humidity level to
the user's desired humidity setting. Frost or
condensation may appear on windows.
On: The thermostat prevents frost or condensation
on windows by not allowing the humidifier to run
above a certain level. To prevent frost or
condensation, the thermostat may turn off the
humidifier before the humidity setting is reached.
See “Window Protection” beginning on page 57.
Table 2. Installer Setup (ISU) Table. (Continued)
ISU
Number
Installer Setup
Name
Settings
Default
Residential,
Commercial
or Both
Notes