![Honeywell VisionPRO 8000 Series Product Data Download Page 34](http://html.mh-extra.com/html/honeywell/visionpro-8000-series/visionpro-8000-series_product-data_2158867034.webp)
VISIONPRO® 8000 SMART THERMOSTAT
33-00096—04
34
1014
Vent During Hum or
Dehum Calls
Yes
No
Yes
Both
This feature is used to help reach the user's desired
humidity level by not allowing the ventilation
equipment to run during a call for humidification or
dehumidification.
Yes: Ventilation is allowed to run during a call for
humidification or dehumidification.
No: Ventilation is NOT allowed to run during a call for
humidification or dehumidification.
1016
Vent On High
Indoor Humidity
Off
On
On
Both
This ISU is only displayed when ISU 1000
Ventilation Type is set to ERV / HRV.
Off: The humidity level has no effect on ventilation.
On: The thermostat removes excess humidity by
turning on the ventilator when the indoor humidity
rises 10% above the user's humidification setting.
The thermostat must be in the heat mode to
ventilate on high humidity.
1017
Ventilator Core
Reminder
Off
3, 6, 9, 12 Calendar Months
Off
Both
Ventilator Core Cleaning Reminder
1017
Ventilator Filter
Reminder
Off
3, 6, 9, 12 Calendar Months
Off
Both
Ventilator Filter Cleaning Reminder
1100
Number of UV
Devices
0, 1, 2
0
Both
Press the up/down arrows to select the number of UV
devices installed in the system. Some systems may
have two UV devices, one for the A-Coil and another
for Air Treatment. A replacement reminder can be
setup for each one. Select 0 if no UV devices are
installed.
1105
UV Bulb 1 Reminder
Note: “1” is not
displayed if there is
only 1 UV Bulb
Off, 6, 12, 24 Calendar Months
Off
Both
UV Bulb 1 Replacement Reminder
1105
UV Bulb 2 Reminder
Off, 6, 12, 24 Calendar Months
Off
Both
UV Bulb 2 Replacement Reminder
1200
Custom Reminders
View / Edit Custom Reminders
Add Custom Reminders
None
Both
See “Customizable Reminders” beginning on
page 72.
28
Backlighting
On Demand
Continuous
On Demand
Both
Select Continuous or On Demand backlighting.
Select Continuous backlighting if you would like the
backlight to be on all the time.
Select On Demand backlighting if you would like the
backlight to only turn on after a key press. After you
complete your changes, the screen stays lit for 45
seconds.
1400
Clock Format
12 hour
24 hour
12
Both
1401
Daylight Saving
Time
Off
On
On
Both
Set to Off in areas that do not follow Daylight Saving
Time.
1402
Indoor Temperature
Offset
-3° F to 3° F (in 1° F increments)
0° F
Both
0° F - No difference in displayed temperature and
the actual room temperature.
The thermostat displays up to 3°F (1.5°C) lower or
higher than the actual measured temperature.
1402
Show humidity on
home screen
Yes
No
Yes
Both
This option is only available if humidifier type and
dehum equipment are both set to none.
Table 2. Installer Setup (ISU) Table. (Continued)
ISU
Number
Installer Setup
Name
Settings
Default
Residential,
Commercial
or Both
Notes