VISIONPRO® 8000 SMART THERMOSTAT
33-00096—04
58
2.
Select the terminals wired to the humidifier. See
Fig. 116.
NOTE:
U1 are Normally Open Dry Contacts that
require power from the system transformer
or a separate transformer. See “Wiring IAQ
Equipment or a Heat/Cool Stage to the U1
Terminals” beginning on page 86.
Fig. 116.
3.
Set Window Protection setting. See Fig. 117.
NOTE:
Internet connection or wired outdoor sensor
is required for Window Protection.
Fig. 117.
4.
Select the system mode(s) to allow humidification.
See Fig. 118.
NOTE:
Heat includes Heat, Emergency Heat and
Auto. If the system is in Auto mode, the ther-
mostat will allow humidification if the last
call was for heat.
Cool includes Cool and Auto. If the system is
in Auto mode, the thermostat will allow
humidification if the last call was for cool. A
discharge sensor is required to humidify in
the Cool mode. The thermostat prevents
condensation in the duct work by not allow-
ing the humidifier to run when the discharge
temperature goes below the dew point tem-
perature. The humidifier is allowed to run
again after the discharge temperature rises
above the dew point temperature.
Fig. 118.
5.
Select from one of the Humidification Control
Options (ISU 807). See Fig. 119.
• Hum when Heat is On
The thermostat turns on the humidifier only if the
heat is currently running and humidification is
needed.
• Hum when Fan is On
The thermostat turns on the humidifier only if the
fan is currently running and humidification is
needed.
• Tstat Controls Fan
The thermostat turns on the humidifier and the
fan when humidification is needed.
• Hum Controls Fan
The thermostat turns on the humidifier when
humidification is needed and the humidifier
controls the fan.
Fig. 119.
6.
Set the desired lockout option. See Fig. 120.