background image

69-1493–1

5

T8400C  ELECTRONIC THERMOSTAT

OPERATION

Setting FAN and SYSTEM Switches

Fan and system settings are controlled manually by using
the switches located at the bottom of the thermostat case.
See Fig. 10.

Fig. 10. Digital display and

Fan and System switches.

FAN Switch

Fan switch settings are:

Auto:  Normal setting for most homes. In cooling, the

fan starts and stops with the cooling equipment. In
heating, the fan is controlled directly by the heating
equipment and may start a few minutes after the
heating equipment turns on (for most systems).
When using an electric heat thermostat, the fan
starts and stops with the heating equipment.

On:  The fan runs continuously. Use for improved air

circulation and air quality.

Slide the FAN switch in the bottom left corner of the
thermostat to select the desired fan setting.

SYSTEM Switch

System switch settings control thermostat operation as
follows:

Cool:  The thermostat controls the cooling system.
Off:  Both heating and cooling are off.
Heat:  The thermostat controls the heating system.

Slide the SYSTEM switch in the bottom right corner of the
thermostat to select the desired system setting.

Set Temperature Setpoint

NOTE:

Temperature setpoint range is 40

°

 to 99

°

F (5

°

 to

37

°

C).

The temperature setpoint and the room temperature are
shown separately on the digital display. The 

▼ 

indicator

points to Set when the temperature setpoint is displayed
and to Room when the room temperature is displayed.

To set temperature setpoint:

1. Select Heat or Cool by sliding the SYSTEM switch in

the lower right corner of the thermostat to the
desired mode. See Fig. 10.

2. To display the temperature setpoints on the digital

display, press either the 

▲ 

or 

▼ 

key once. The

temperature setpoint is displayed for approximately
five seconds as the indicator points to Set and
flashes.

3. To increase the temperature setpoint, press the 

key. Each press changes the setpoint one degree;
press and hold to change the setpoint several
degrees.

4. To decrease the temperature setpoint, press the 

key. Each press changes the setpoint one degree;
press and hold to change the setpoint several
degrees.

Setting 

°

F/

°

C Indication and Heat Cycle Rate

NOTE: To save changes to the 

°

F/

°

C indication and

the heat cycle rate, all seven steps must be
completed.

To set the 

°

F/

°

C indication and heat cycle rate:

1. If the temperature is displayed in 

°

F, set the

temperature setpoint to 52

°

F. If the room tempera-

ture is displayed in 

°

C, set the temperature setpoint

to 11

°

C.

M14682

M14683

SYSTEM

Cool  Off  Heat

Auto  On

FAN

M14678A

TEMPERATURE DISPLAY

INCREASE SETTING

DECREASE SETTING

FAN SWITCH

SYSTEM SWITCH

Set

Room  

Set

Room  

INDICATOR

ROOM TEMPERATURE

SETPOINT TEMPERATURE

M14679

M14680

M14681

Summary of Contents for TRADELINE T8400C

Page 1: ...ctronicThermostat INSTALLATION When Installing this Product 1 Read these instructions carefully Failure to follow them could damage the product or cause a hazard ous condition 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After installation is complete check o...

Page 2: ...ions normally even when not level Mount wallplate with the screws provided see Fig 2 as follows 1 Place the wallplate at the desired location on the wall 2 Pull the thermostat wire through the wallplate entrance hole 3 Select the two mounting holes that best fit the application 4 Fasten the wallplate to the wall using the anchors and screws provided 5 After wiring the wallplate plug the hole to pr...

Page 3: ...g the T8400C Thermostat All wiring must comply with local electrical codes and ordinances Disconnect the power supply to prevent electrical shock or equipment damage NOTE To ensure proper mounting of thermostat restrict all wiring to the shaded area See Fig 4 The shape of the terminals permits insertion of straight or wraparound wiring connections either method is accept able See Fig 5 Fig 4 Restr...

Page 4: ...TION AS REQUIRED REMOVE RC TO R JUMPER WHEN INSTALLED ON A TWO TRANSFORMER SYSTEM CAN BE USED FOR CHANGEOVER VALVE ON SINGLE STAGE HEAT PUMP SYSTEMS POWER TO R TERMINAL IS REQUIRED WHEN THE SYSTEM SWITCH IS IN THE OFF POSITION 2 3 3 1 1 3 4 Fig 9 Mounting thermostat to wallplate L1 HOT L2 1 COOL CHANGEOVER FAN RELAY COOL RELAY HEAT RELAY 24V M13277A HEAT CHANGEOVER TRANSFORMER 1 POWER SUPPLY PROVI...

Page 5: ... setpoint and the room temperature are shown separately on the digital display The indicator points to Set when the temperature setpoint is displayed and to Room when the room temperature is displayed To set temperature setpoint 1 Select Heat or Cool by sliding the SYSTEM switch in the lower right corner of the thermostat to the desired mode See Fig 10 2 To display the temperature setpoints on the...

Page 6: ...indication 6 Press the key to display the heat cycle rate of 1 3 4 5 6 9 or 12 If the desired cycle is displayed press the key to exit the installer setup mode To change the heat cycle rate press the key to scroll between 1 3 4 5 6 9 and 12 Stop scrolling when the desired rate is displayed See Table 1 for the cycle rate options and the corresponding system equipment a High Efficiency Furnace b Ref...

Page 7: ...m temperature After approximately five minutes the cooling equipment should start The fan starts and stops with the cooling equipment 3 Press the key to raise the temperature setting above the room temperature Cooling system should shut down NOTE To bypass the five minute delay see Optional System Checkout section Fan 1 Slide the SYSTEM switch to Off and the FAN switch to On The fan should run con...

Page 8: ... Limited Honeywell Limitée 35 Dynamic Drive Scarborough Ontario M1V 4Z9 Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley MN 55422 Printed in U S A on recycled paper containing at least 10 post consumer paper fibers www honeywell com yourhome ...