T8400C  ELECTRONIC THERMOSTAT

TERMINAL 
SCREW

M13274

G

Rc

R

Y

W

B

O

FOR STRAIGHT INSERTION
STRIP 5/16 IN. (8 MM)

FOR WRAPAROUND
STRIP 7/16 IN. (11 MM)

L1 
(HOT)

L2

1

1

COOLING
CONTACTOR

FAN
RELAY

HEATING
PRIMARY
CONTROL

24V

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.

FACTORY INSTALLED JUMPER.

M13275

Y

G

Rc

W

R

B

O

2

2

KEEP WIRING IN
SHADED AREA

MOUNTING 
SCREW HOLE

MOUNTING 
SCREW HOLE

WIRING ENTRANCE
HOLE

M16432

G

Rc

R

Y

W

B

O

Wiring

IMPORTANT

Use an 18-gauge maximum wire for wiring the
T8400C Thermostat.

All wiring must comply with local electrical codes and
ordinances. Disconnect the power supply to prevent
electrical shock or equipment damage.

NOTE:

To ensure proper mounting of thermostat, restrict
all wiring to the shaded area. See Fig. 4.

The shape of the terminals permits insertion of straight or
wraparound wiring connections; either method is accept-
able. See Fig. 5.

Fig. 4. Restrict wiring to shaded area.

Fig. 5. Wiring connections.

The T8400C Thermostat is powered through the heating/
cooling system controls and is adaptable to most 4-wire,
24 Vac heating-cooling systems.

Refer to Fig. 6, 7, and 8 for typical wiring hookups.

Fig. 6. Typical hookup of T8400C in heat-cool system

with single transformers.

Summary of Contents for TRADELINE T8400C

Page 1: ...ctronicThermostat INSTALLATION When Installing this Product 1 Read these instructions carefully Failure to follow them could damage the product or cause a hazard ous condition 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After installation is complete check o...

Page 2: ...ions normally even when not level Mount wallplate with the screws provided see Fig 2 as follows 1 Place the wallplate at the desired location on the wall 2 Pull the thermostat wire through the wallplate entrance hole 3 Select the two mounting holes that best fit the application 4 Fasten the wallplate to the wall using the anchors and screws provided 5 After wiring the wallplate plug the hole to pr...

Page 3: ...g the T8400C Thermostat All wiring must comply with local electrical codes and ordinances Disconnect the power supply to prevent electrical shock or equipment damage NOTE To ensure proper mounting of thermostat restrict all wiring to the shaded area See Fig 4 The shape of the terminals permits insertion of straight or wraparound wiring connections either method is accept able See Fig 5 Fig 4 Restr...

Page 4: ...TION AS REQUIRED REMOVE RC TO R JUMPER WHEN INSTALLED ON A TWO TRANSFORMER SYSTEM CAN BE USED FOR CHANGEOVER VALVE ON SINGLE STAGE HEAT PUMP SYSTEMS POWER TO R TERMINAL IS REQUIRED WHEN THE SYSTEM SWITCH IS IN THE OFF POSITION 2 3 3 1 1 3 4 Fig 9 Mounting thermostat to wallplate L1 HOT L2 1 COOL CHANGEOVER FAN RELAY COOL RELAY HEAT RELAY 24V M13277A HEAT CHANGEOVER TRANSFORMER 1 POWER SUPPLY PROVI...

Page 5: ... setpoint and the room temperature are shown separately on the digital display The indicator points to Set when the temperature setpoint is displayed and to Room when the room temperature is displayed To set temperature setpoint 1 Select Heat or Cool by sliding the SYSTEM switch in the lower right corner of the thermostat to the desired mode See Fig 10 2 To display the temperature setpoints on the...

Page 6: ...indication 6 Press the key to display the heat cycle rate of 1 3 4 5 6 9 or 12 If the desired cycle is displayed press the key to exit the installer setup mode To change the heat cycle rate press the key to scroll between 1 3 4 5 6 9 and 12 Stop scrolling when the desired rate is displayed See Table 1 for the cycle rate options and the corresponding system equipment a High Efficiency Furnace b Ref...

Page 7: ...m temperature After approximately five minutes the cooling equipment should start The fan starts and stops with the cooling equipment 3 Press the key to raise the temperature setting above the room temperature Cooling system should shut down NOTE To bypass the five minute delay see Optional System Checkout section Fan 1 Slide the SYSTEM switch to Off and the FAN switch to On The fan should run con...

Page 8: ... Limited Honeywell Limitée 35 Dynamic Drive Scarborough Ontario M1V 4Z9 Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley MN 55422 Printed in U S A on recycled paper containing at least 10 post consumer paper fibers www honeywell com yourhome ...

Reviews: