Mini-AT User Guide
The Scheduled Call-In feature also requires the Mini-AT to issue AT commands to a Messenger
Modem. This feature is designed to interface with third party software applications that can accept a sched-
uled call-in from a remote site.
To use this method, set the following items:
333
Call-in Trigger
2 - Scheduled Call-in only
334
Scheduled Call-in date
desired date of call
335
Scheduled Call-in time
desired time of call
339
Scheduled Call-In Phone#
Phone number to call at scheduled time
486
Modem AT Enable
1 - Call-in via AT commands
491
Modem Init String
Initialization command of the modem
Default = &F
492
Modem Dial String
Command sent to initiate dialing
Default = ATDT
494
Modem Hang-up String
Command sent to modem for hang-up
Default = ATH
495
Modem Retry Interval A
Time to wait for a retry if first call fails
Default = 5 (value is in minutes)
496
Modem Retry Interval B
Time to wait for a retry if all calls fail
Default = 1440 (value is in minutes)
Note: After each Scheduled Call-in, the date in item 334 must be changed to reflect the next
desired call-in date. Otherwise the instrument will not call-in again.
The Mini-AT can also be configured to call-in for both the scheduled and alarm case. In order to configure the
instrument for this method the following items must be set:
333
Call-In Trigger
3 - Alarm & Scheduled Call-in
334
Scheduled Call-in date
desired date of call
335
Scheduled Call-in time
desired time of call
339
Scheduled Call-In Phone#
Phone number to call at scheduled time
486
Modem AT Enable
1 - Call-in via AT commands
491
Modem Init String
Initialization command of the modem
Default = &F
492
Modem Dial String
Command sent to initiate dialing
Default = ATDT
493
Alarm Call-In Phone #
Phone number to call for alarm
494
Modem Hang-up String
Command sent to modem for hang-up
Default = ATH
495
Modem Retry Interval A
Time to wait for a retry if first call fails
Default = 5 (value is in minutes)
496
Modem Retry Interval B
Time to wait for a retry if all calls fail
Default = 1440 (value is in minutes)
Summary of Contents for Mini-AT
Page 2: ...2 www honeywell com ...
Page 138: ...138 www honeywell com Mini AT User Guide Mini AT Door ...
Page 140: ...140 www honeywell com Mini AT User Guide Meter Mount Mini AT ...
Page 142: ...142 www honeywell com Mini AT User Guide Wall Mount Mini AT ...
Page 144: ...144 www honeywell com Page 144 Mini AT User Guide ...
Page 145: ...145 Page 145 Mini AT User Guide ...
Page 146: ...146 www honeywell com Page 146 Mini AT User Guide ...
Page 147: ...147 Page 147 Mini AT User Guide ...
Page 148: ...148 www honeywell com Page 148 Mini AT User Guide ...
Page 149: ...149 Page 149 Mini AT User Guide ...
Page 150: ...150 www honeywell com Page 150 Mini AT User Guide ...