174
REPORT TRIGGER 10
When activated, this trigger will cause an audit trail entry to time-
stamp
Alarms Cleared
, either manually or automatically by RBX.
The Clear Alarm action will also provide an alarm output pulse and
change item 176 (RBX ALARM EVENT) from “00000000” to
“11111111” if item 165 (RBX ALARM ENABLE) is set to RBX
Alarms (code
1
).
Select:
0
- Inactive
1
- Activated-----
Default
175
REPORT TRIGGER 11
When activated, this trigger will cause an audit trail entry to time-
stamp instrument
Shutdown
.
Select:
0
- Inactive
1
- Activated-----
Default
176
RBX ALARM EVENT
This item provides an indication of RBX alarm activity since last
interrogated. It normally displays “00000000” and is internally set
to “11111111” when any alarm becomes activate or is cleared. It
must be externally resetto “00000000” after each interrogation (if
needed) to determine the status of future changes.
Default
= 00000000
177
PULSE REPETITION
The amount of time (in hours) an alarm pulse will be PERIOD
retransmitted if the current alarm(s) have not been acknowledged
(read). Setting this item to “0” will disable this feature. Integer
values only, fractions are not allowed.
Range: 0 to 24
Default
= 24
183
PREV DAY CORVOL
Yesterday’s Daily Corrected Volume, i.e., the daily corrected
volume that is one ‘Gas Day’ old at the time the instrument was
accessed. This information is updated with the value from item
223 at the beginning of every new gas day. Note: The gas day
begins at the time entered at item 205.
Default
= 00000000
184
PREV DAY UNCVOL
Yesterday’s Daily Uncorrected Volume, i.e., the daily uncorrected
volume that is one ‘Gas Day’ old at the time the instrument was
accessed. This information is updated with the value from item
224 at the beginning of every new gas day. Note: The gas day
begins at the time entered at item 205.
Default
= 00000000
Summary of Contents for Mini-AT
Page 2: ...2 www honeywell com ...
Page 138: ...138 www honeywell com Mini AT User Guide Mini AT Door ...
Page 140: ...140 www honeywell com Mini AT User Guide Meter Mount Mini AT ...
Page 142: ...142 www honeywell com Mini AT User Guide Wall Mount Mini AT ...
Page 144: ...144 www honeywell com Page 144 Mini AT User Guide ...
Page 145: ...145 Page 145 Mini AT User Guide ...
Page 146: ...146 www honeywell com Page 146 Mini AT User Guide ...
Page 147: ...147 Page 147 Mini AT User Guide ...
Page 148: ...148 www honeywell com Page 148 Mini AT User Guide ...
Page 149: ...149 Page 149 Mini AT User Guide ...
Page 150: ...150 www honeywell com Page 150 Mini AT User Guide ...