099
BATTERY LOW
This item (099) indicates if a low voltage alarm for the main
battery was generated. During a wake-cycle, if the
measurement for item 048 (BATTERY VOLTAGE) is a value
less than the value at item 049 (BATTERY LOLIM V), an
alarm is initiated and is indicated by placing dots on the LCD
and “11111111” at item 099. “00000000” at item 099
indicates there is no Low Battery Alarm. The alarm indicators
will remain active until manually cleared (by software) or
automatically when RBX (item 165) is enabled.
Default
= 00000000
100
BATT CYCLES ALRM
This item (100) indicates if a high wake-cycle alarm for the
main battery was generated. During a wake-cycle, if the
calculated value for item 059 (BATTERY WAKE-UP
CYCLES) is a value greater than the value at item 060 (BATT
CYCLES LIM), an alarm is initiated and is indicated by
placing dots on the LCD and “11111111” at item 100.
“00000000” at item 100 indicates there is no Battery Cycles
Alarm. The alarm indicators will remain active until manually
cleared (by software).
Default
= 00000000
101
BKUP BATTERY LOW
This item (101) indicates if a low voltage alarm for the backup
battery was generated. During a wake-cycle, if the
measurement for item 051 (MEMORY BATTERY
VOLTAGE) is a value less than the value at item 052 (MEM
BATT LOVOLT LIMIT), an alarm is initiated and is indicated
by placing dots on the LCD and “11111111” at item 101.
“00000000” at item 101 indicates there is no Low Mem
Battery Alarm. The alarm indicators will remain active until
manually cleared (by software) or automatically when RBX
(item 165) is enabled.
Default
= 00000000
102
INDEX SW#1 FAULT
This item (102) indicates if an alarm for index switch #1 was
generated. If index switch #1 fails to provide an input meter
pulse within four meter revolutions, an alarm is initiated and is
indicated by placing dots on the LCDand “11111111” at item
101. “00000000” at item 101indicates there is no Switch #1
Alarm. The alarm indicators will remain active until manually
cleared (by software).
Default
= 00000000
Summary of Contents for Mini-AT
Page 2: ...2 www honeywell com ...
Page 138: ...138 www honeywell com Mini AT User Guide Mini AT Door ...
Page 140: ...140 www honeywell com Mini AT User Guide Meter Mount Mini AT ...
Page 142: ...142 www honeywell com Mini AT User Guide Wall Mount Mini AT ...
Page 144: ...144 www honeywell com Page 144 Mini AT User Guide ...
Page 145: ...145 Page 145 Mini AT User Guide ...
Page 146: ...146 www honeywell com Page 146 Mini AT User Guide ...
Page 147: ...147 Page 147 Mini AT User Guide ...
Page 148: ...148 www honeywell com Page 148 Mini AT User Guide ...
Page 149: ...149 Page 149 Mini AT User Guide ...
Page 150: ...150 www honeywell com Page 150 Mini AT User Guide ...