Mini-AT User Guide
Item
No.
Item Name
Description
————————————————————————————————————————
460
ZERO RATE DETECTION Parameter to disable/enable zero flow rate detection as well as
apply a scaling factor to the calculated expectation time period.
A value of ‘0’ disables Zero-Flow Detection. A value greater
than zero will enable Zero-Flow Detection. Range: 0 to 60
Default =
2
461
RATE LOW ALARM
This item indicates if a Low Flow Rate alarm was generated.
If the value calculated at item 209 was less than the value
entered at item 462, an alarm is initiated and is indicated by
placing dots on the LCD and “11111111” at item 461.
“00000000” at item 461 indicates there is no Low Flow Alarm.
The alarm indicators will remain active until manually cleared
or automatically when RBX is enabled. This alarm can be
disabled by setting the value at item 462 to “0.0”.
Default =
00000000
482
DEFAULT DISPLAY
Parameter used to select which item will be displayed on the
LCD when the instrument is in corrector mode. Any item may
be selected, but traditionally corrected volume is displayed
Default
= 000 (Corrected Volume)
486
MODEM AT ENABLE
Selection to determine the type of call-in initiated by the
instrument.
Select:
0
-Call-in via Alarm Pulse
Default
1
-Call-in via AT commands
491
MODEM INIT STRING
Character string used to initialize instrument modem at the
beginning of call-in.
Default
= &f
492
MODEM DIAL STRING
Character string used to initiate dialing
Default
= ATDT
493
ALARM CALL-IN #
Telephone number dialed when Alarm call-in is executed.
494
MODEM HANG-UP
Character string used by to disconnectmodem communications
Default
= ATH
495
MDM RETRY INTVL A
Retry period A, in minutes. Intended to be the primary retry.
Default
= 5
496
MDM RETRY INTVL B
Retry period B, in minutes. Intended to be the secondary retry.
Default
= 1440
497
MDM RETRY COUNT A
Number of period A retries
Default
= 3
Summary of Contents for Mini-AT
Page 2: ...2 www honeywell com ...
Page 138: ...138 www honeywell com Mini AT User Guide Mini AT Door ...
Page 140: ...140 www honeywell com Mini AT User Guide Meter Mount Mini AT ...
Page 142: ...142 www honeywell com Mini AT User Guide Wall Mount Mini AT ...
Page 144: ...144 www honeywell com Page 144 Mini AT User Guide ...
Page 145: ...145 Page 145 Mini AT User Guide ...
Page 146: ...146 www honeywell com Page 146 Mini AT User Guide ...
Page 147: ...147 Page 147 Mini AT User Guide ...
Page 148: ...148 www honeywell com Page 148 Mini AT User Guide ...
Page 149: ...149 Page 149 Mini AT User Guide ...
Page 150: ...150 www honeywell com Page 150 Mini AT User Guide ...