7 - 1
7
EAS Settings
EAS Considerations
Do not install any large iron fixtures, such as steel support poles, near the Genesis 7580g. Doing so may re-shape the EAS tag
deactivation field.
EAS Deactivation
The Genesis 7580g supports deactivation of Checkpoint EAS tags. The following illustration shows the location of the EAS
deactivation area. It is important to pass the entire tag through this area to deactivate the security tag.
Note: Do not store tags within 18.0 in (45.7cm) of the Genesis 7580g. Tags stored closer than 18.0 in (45.7cm) may be
unintentionally deactivated. This area also includes storage areas located under the Genesis 7580g.
EAS Deactivation Zone
Side Deactivation Area
Expected
Deactivation
Range
F
a
c
e
/W
in
d
o
w
S
u
rfa
c
e
8.7 in (22cm)
7.9 in (20cm)
6.6 in (16.8cm)
3.9 in (10cm)
7.9 in (20cm)
5.5 in (14cm)
Top Deactivation Area
Face/Window Surface
11.36
°
8.4 in (21.4cm)
11.36
°
8.4 in (21.4cm)
Expected
Deactivation
Range
8.7 in (22cm)
Summary of Contents for Genesis 7580G
Page 1: ...Genesis 7580g Presentation Area Imager User s Guide ...
Page 6: ......
Page 14: ...viii ...
Page 80: ...5 14 ...
Page 130: ...6 50 ...
Page 134: ...7 4 ...
Page 176: ...11 22 ...
Page 184: ...13 4 ...
Page 199: ...Programming Chart 0 1 2 3 4 5 6 7 8 9 ...
Page 200: ......