2 - 21
XON/XOFF
Standard ASCII control characters can be used to tell the scanner to start sending data (
XON/XOFF On
) or to stop sending
data (
XON/XOFF Off
). When the host sends the XOFF character (DC3, hex 13) to the scanner, data transmission stops.
To resume transmission, the host sends the XON character (DC1, hex 11). Data transmission continues where it left off
when XOFF was sent.
Default = XON/XOFF Off
.
ACK/NAK
After transmitting data, the scanner waits for an ACK character (hex 06) or a NAK character (hex 15) response from the
host. If ACK is received, the communications cycle is completed and the scanner looks for more bar codes. If NAK is
received, the last set of bar code data is retransmitted and the scanner waits for ACK/NAK again. Turn on the ACK/NAK
protocol by scanning the
ACK/NAK On
bar code below. To turn off the protocol, scan
ACK/NAK Off
.
Default = ACK/NAK
Off
.
Scanner to Bioptic Communication
The following settings are used to set up communication between Honeywell scanners and bioptic scanners.
Note: The scanner’s baud rate must be set to 38400 and the RS232 timeout must be set to 3000 in order to communicate with
a bioptic scanner. See "RS232 Modifiers" on page 2-18, and
on page 2-20 for further information.
Scanner-Bioptic Packet Mode
Packet Mode On
must be scanned to set the scanner’s format so it is compatible with a bioptic scanner.
Default = Packet
Mode Off.
XON/XOFF On
* XON/XOFF Off
ACK/NAK On
* ACK/NAK Off
* Packet Mode Off
Packet Mode On
Summary of Contents for Genesis 7580G
Page 1: ...Genesis 7580g Presentation Area Imager User s Guide ...
Page 6: ......
Page 14: ...viii ...
Page 80: ...5 14 ...
Page 130: ...6 50 ...
Page 134: ...7 4 ...
Page 176: ...11 22 ...
Page 184: ...13 4 ...
Page 199: ...Programming Chart 0 1 2 3 4 5 6 7 8 9 ...
Page 200: ......