Codes [42, Quick Menu 7]
Galaxy Flex Installer Manual
68
Template [42.1.User code.9]
An Access Template controls the areas to which a user has access, and also the access times.
Once a template is created in
Access Template [45.6]
it can be assigned to multiple users.
This eliminates repetitive programming of common door access rights for multiple users.
If no access template is allocated to a user, access rights for that user are defined by the
Groups to which the user is allocated. This means the user has access through any door
configured to a Group that is common to the user's group allocation.
Note:
By assigning a template only the groups assigned in the template control the groups
to which the card has access. The groups assigned to the User Code no longer
control access for the card.
Radio Fob [42.1.User code.10]
Use this option to register a keyfob on the system. Keyfobs can be assigned to a maximum
of 98 users (depending on the system model), and can be programmed to set/unset or
activate panic alarms, or both. These options may be limited by certain regional restrictions.
To register a keyfob:
1.
Select
1=Learn Fob
, and then press
ent
.
The serial number is shown if a fob has been programmed.
2.
If you enter the serial number manually, select the device type:
1=Alpha
or
2=V2
.
3.
Press
to start the self-learn process. The message
User Awaiting Fob
is displayed.
4.
On the keyfob, press both SOS buttons (buttons 1 and 3) together.
If successful, the message
Fob learned
is displayed for 3 seconds. If menu option
51.60.8 is enabled you will hear a double beep.
If no device is detected within 30 seconds, the message
Self Learn Timed Out
is
displayed.
5.
If required, and if the feature is available, select
1=Enabled
to enable the Panic
function on the keyfob.
Note:
In some regions this feature may be disabled.
If the keyfob does not learn:
1.
Remove the battery.
2.
Short circuit the battery terminals.
3.
Replace the battery and repeat the above procedure.
To enable the panic function on an existing keyfob:
Note:
Enable
[51.60.2]
before selecting this option.
1.
Select
2=Fob PA
, and then press
ent
.
2.
Select
1=Enabled
.