Audio [56.6]
Use this option to setup Audio Transmission to allow audio verification of an alarm. Each
system zone can be assigned one audio channel, each with a maximum of three
microphones. Following an alarm transmission over PSTN, you can program the panel to
route recorded audio from the time of the alarm activation, and live audio, direct to the
Alarm Receiving Centre. The following options are available:
1 = Listen In ((0 = Disabled, 1 = Enabled)
2 = Audio Channels
Select Audio Channel ((0 = Disabled, 1 = Enabled)
3 = Pre-Alarm – Pre Listen Time 00 (0 to 10 sec, the default is 5)
Listen In [56.6.1]
Use this option to allow onsite audio verification by an operator, after the panel sends an
alarm signal to the ARC (
0=Disabled
,
1=Enabled)
.
Audio Module [56.6.2]
Use this
option to control the audio channels’ status. Select an audio channel to enable or
disable.
The channel is in a four-digit format. For example: Channel 9024.
9=Line number (fixed)
0=Audio Interface number (fixed)
2=Mux Module number
4=Audio channel
Press
ent
to display the status of the current audio channel, for example:
Press
ent
again to disable the audio channel.
Pre-Alarm [56.6.3]
Use this option to set the alarm delay recording time. The audio channel continuously
records a rolling 10 seconds of audio. When an alarm activation occurs, the system stops
recording and stores 10 seconds of audio. Use the pre-listen time parameter to set the
amount of alarm delay in the recorded audio.
Pre-Listen Time
The alarm delay listen time can be set from 0 to 10 seconds. Setting the time to 5 seconds
(default) means that 5 seconds of pre-alarm and 5 seconds of post alarm audio is saved.
CHANNEL 9024
[ent] to select
ENABLED 9024 E
0=DISABLED
E = enabled, D = disabled