Soak [55]
Galaxy Flex Installer Manual
136
Soak [55]
Use the Soak option to test selected zones for a period ranging from 1 to 14 days. Program
the
Soak Time [51.16]
before starting a soak test.
Zones that activate on soak test do not cause alarms but are recorded in the event log and are
reported to type 2 (and above) users when the system is unset. At the end of the soak test
period, zones revert to normal operation.
The Soak Time is reset to the full number of days if there is an alarm activation on any of
the selected zones.
The Soak Time starts when the first zone is put onto soak test. Subsequent additions are only
tested for the period remaining in the Soak Time.
Activation of an Exit or Video Exit zone during the Entry Time does not reset the soak test
and period.
To program Soak Zones:
When you select the Soak option, the address and function of the first zone on the system is
displayed.
1.
Use
A
or
B
to select a zone, or enter the zone address directly, and then press
#
.
ON
TEST
is displayed on the keypad.
2.
Repeat step 1. to add more zones to the test.
3.
Once all the zones have been selected, press
esc
. The keypad briefly displays the
number of days remaining in the test.